WSC 304 01 install WMa 200547 0611-UK   ©WindowMaster 2005, 2011  ®Windowmaster is a registered trademark used under licence by WindowMaster Group 

 

 
 

 

WSC 304 01 

Smoke control unit  

Operating manual / Technical information 

 

 
 

 

 

 

 

 

 

 

 

 

 

Table of contents: 

Safety information 

Operating elements and fuse review 

Technical function description 

Technical data 

Installation 

Cable lengths table 

Cable plan 

Standard wiring diagram 

Various wiring diagrams 

Commisioning  

Maintenance  

 

www.WindowMaster.com

 

WindowMaster A/S Skelstedet 13 2950 Vedbæk 

Danmark

 Tel.: +45 4567 0300 Fax: +45 4567 0390 

WindowMaster GmbH Zum Bache 4 32549 Bad Oeynhausen 

Deutschland

 Tel.: +49 (0) 5731-7583-0 Fax: +49 (0) 5731-7583-79 

WindowMaster Control Systems Ltd. UNIT 21 Port Tunnel Business Park Dublin 17 

Ireland 

Tel: +353 (0) 1894 1444 Fax: +44 (0) 1536 526321 

WindowMaster AG Industriestrasse 7 4632 Trimbach 

Schweiz

 Tel.: +41 (0) 62 289 22 22 Fax: +41 (0) 62 289 22 20 

WindowMaster Control Systems Ltd. Kettering Parkway Wellingborough Road Kettering Northants NN15 6XR 

United Kingdom

 Tel.: +44 (0) 1536 510990 Fax: +44 (0) 1536 526321 

 

Содержание WSC 304 01

Страница 1: ...Commisioning Maintenance www WindowMaster com WindowMaster A S Skelstedet 13 2950 Vedb k Danmark Tel 45 4567 0300 Fax 45 4567 0390 WindowMaster GmbH Zum Bache 4 32549 Bad Oeynhausen Deutschland Tel 49...

Страница 2: ...onnection Leave the insulation of the power supply cable in place up to the mains terminal Manufacturer s declaration The central control system is exclusively designed for the automatic closing of sm...

Страница 3: ...review WSC 304 01 ____________________________________________________________________________ Smoke control unit WSC 304 01 3 Operating Accu Motor Alarm Mains Motor Smoke det SHE switch SHE display...

Страница 4: ...reak glass unit are lit The yellow malfunction LED in the break glass unit flashes Resetting a trip caused by high temperature The smoke extraction system can be closed again by pressing the Reset but...

Страница 5: ...ter ventilation OPEN or ventilation STOP This function is not operative if the setting potentiometer is on the right hand stop Wind rain CLOSE The actuators close when the wind rain sensor has tripped...

Страница 6: ...must be specially made in the production by using a special software ASV CLOSE When ASV CLOSE is tripped all actuators automatically CLOSE An acoustic alarm signal sounds continuous sound in the break...

Страница 7: ...SW2 SW 2 1 ON The smoke control system trips by a malfunction signal from the motor smoke detector or break glass unit SW 2 1 OFF The smoke control system does not trip by a malfunction signal The ma...

Страница 8: ...over contact max load 60V 1A with 3 pole connection terminal for potential free transmission to the BMS panel etc 2 pole connection terminal for 2 wire BUS cable for the feedback of malfunctions in c...

Страница 9: ...r the installation position Open central control and remove the housing top section door from the housing bottom section Fasten the housing bottom section in the wall cut out cut out dimension 335 x 3...

Страница 10: ...ble network for smoke ventilation systems Cable system ends at the interface junction box for the actuator The flexible heat resistant connection cable of the smoke ventilation system actuator is part...

Страница 11: ...Cable plan ____________________________________________________________________________ Smoke control unit WSC 304 01 11...

Страница 12: ...Standard wiring diagram __________________________________________________________________________ Smoke control unit WSC 304 01 12 WLA 330 WLA331 WSA 300 WSA 310...

Страница 13: ...Various wiring diagrams ____________________________________________________________________________ Smoke control unit WSC 304 01 13...

Страница 14: ...Various wiring diagrams ____________________________________________________________________________ Smoke control unit WSC 304 01 14...

Страница 15: ...e the protection film from one face of the supplied foam rubber Glue each foam rubber to the bottom side of the accumulators Connect the accumulators to the black accumulator bridge according to the w...

Страница 16: ...relevant regulations b The green mains and operating LED s are OFF the yellow accumulator Led is flashing control unit in the accumulator mode The malfunction message at the break glass unit is ON c T...

Страница 17: ...ystem Check fastening and clamping screws for firm seating Carry out a test run of the entire system see chapters Start up and Test Run Only have defective units repaired in our factory Only install o...