background image

3

OPM-115

REV A

A. Operate only in well ventilated areas.

B. Never operate indoors including attached garages

C. Never operate the unit in such a way as to allow exhaust gases

to seep back into closed rooms (i.e. through windows, walls,

floors).

4. NOISE HAZARD -

Excessive noise is not only tiring, but continual exposure can lead to

loss of hearing.

A. Use hearing protection when working around this equipment for

long periods of time.

B. Keep your neighbors in mind when using this equipment.

5. CLEANLINESS -

Keep the generator and surrounding area clean.

A. Remove all grease, ice, snow or materials that create

slippery conditions around the unit.

B. Remove any rags or other materials that could create a

potential fire hazard.

C. Carefully clean up any gas or oil spills before starting the unit.

6. SERVICING EQUIPMENT -

All service, including the installation or replacement of service parts,

should be performed only by a qualified technician.

A. Use only factory approved repair parts.

B. Do not work on this equipment when fatigued.

C. Never remove the protective guards, covers, or receptacle

panels while the engine is running.

D. Use extreme caution when working on electrical components.

High output voltage from this equipment can cause serious

injury or death.

E. Always avoid hot mufflers, exhaust manifolds, and engine parts.

They can cause severe burns instantly.

F. The use of the engine-generator set must comply with all

national, state, and local codes.

SAFETY INFORMATION

This engine generator set has been designed and manufactured to 

allow safe, reliable performance. Poor maintenance, improper or 

careless use can result in potentially deadly hazards; from electrical 

shock, exhaust gas asphyxiation, or fire. Please read all safety 

instructions carefully before installation or use. Keep these instructions 

handy for future reference. Take special note and follow all warnings on 

the unit labels and in the manuals.

ANSI SAFETY DEFINITIONS

DANGER:

DANGER indicates an imminently hazardous situation which, if not 

avoided, will result in death or serious injury. This signal word is to be 

limited to the most extreme situations.

WARNING:

WARNING indicates a potentially hazardous situation which, if not 

avoided, could result in death or serious injury.

CAUTION:

CAUTION indicates a potentially hazardous situation which, if not 

avoided, may result in minor or moderate injury. It may also be used to 

alert against unsafe practices.

1. ELECTRICAL SHOCK -

The output voltage present in this equipment can cause fatal electric

shock. This equipment must be operated by a responsible person.

A. Do not allow anyone to operate the generator without proper

instruction.

B. Guard against electric shock.

C. Avoid contact with live terminals or receptacles.

D. Use extreme care if operating this unit in rain or snow.

E. Use only three-pronged grounded receptacles

and extension cords.

F. Be sure the unit is properly grounded to an

external ground rod driven into the earth.

2. FIRE HAZARD -

Gasoline and other fuels present a hazard of possible explosion and/

or fire.

A. Do not refuel when the engine is running or hot.

B. Keep fuel containers out of reach of children.

C. Do not smoke or use open flame near the generator set or fuel

tank.

D. Keep a fire extinguisher nearby and know its proper use.

Fire extinguishers rated ABC by NFPA are appropriate.

E. Store fuel only in an approved container, and only in a well

ventilated area.

F. Follow local codes for closeness to combustible material.

3. DEADLY EXHAUST GAS -

Exhaust fumes from any gasoline engine contain carbon monoxide, an

invisible, odorless and deadly gas that must be mixed with fresh air.

TESTING POLICY

Before any generator is shipped from the factory, it is fully checked 

for performance. The generator is loaded to its full capacity, and the 

voltage, current, and frequency are carefully checked.

Rated output of generator is based on engineering tests of typical units, 

and is subject to, and limited by, the temperature, altitude, fuel, and 

other conditions specified by the manufacturer of applicable engines.

This unit comes factory set for either key start or manual start. With the 

DSE 7310 MKII controller used in the manual start option it is possible 

to wire the control for remote start. Wiring instructions can be found 

further in this manual. The key start version does not have this option.

Содержание DX100F4

Страница 1: ...RT 5 9 6 216 5 9 51 6 5 37 21 7 25 1 7 0 12 3 57 180 5 6 5 37 21 9 2 1 1 1 7 1 5 725 8 6 5 0 66 0 5 5 77 5 7 2 7 7 867 6 67 6 3 67 9 81 76 1 5 211 7 2 7 7 50 1 2 6 77 5 5 5 7 9 03 286 1 167 7 2 1 1 51...

Страница 2: ...fully read and follow the operating instructions in this manual Should you experience a problem please follow the Troubleshooting Tables near the end of this manual The warranty listed in the manual d...

Страница 3: ...nal word is to be limited to the most extreme situations WARNING WARNING indicates a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION CAUTION indica...

Страница 4: ...5 1D or 2D EN590 or equivalent Oil Type SEE LUBRICATION SECTION Oil Capacity 17 9 Quarts Cooling System 50 50 mix DX130F4 Generator Wattage 109 000 130 000 123 000 130 000 kVa 109 162 154 102 Volts 12...

Страница 5: ...120 240 277 480 Phase Three Three Three PF 80 80 80 Amps 1215 1051 526 CB Size 800 800 800 Hertz 60 60 60 Engine Model FPT C13 TTE3X 13L Starting System 24 Volt Muffler Standard Fuel Consumption full...

Страница 6: ...s phase Excitor Stator Resistance 18 0 ohms Excitor Rotor Resistance 0 068 ohms phase cycles set points and signal output capabilities are possible Consult factory for procedure and passwords NOTICE T...

Страница 7: ...t for any damage If any damage is noted it is always easiest to refuse the shipment and let WINCO take care of the freight claim If you sign for the unit the transfer of the ownership requires that yo...

Страница 8: ...ine wear and shorten its useful life COOLANT Before starting the engine check the coolant level in the radiator If it is low refill as specified in the engine manufacturer s maintenance instructions T...

Страница 9: ...d state The battery can be left on this mode indefinitely During this mode the green LED will be on constantly This charger is mounted under the customer connection on the control side of the generato...

Страница 10: ...eptacles A C B D E A C ELECTRICAL CONNECTIONS NOTICE CLASS 1 WIRING METHODS ARE TO BE USED FOR ALL FIELD WIRING CONNECTIONS TO TERMINALS OF A CLASS 2 CIRCUIT All wiring must be completed in accordance...

Страница 11: ...110 Standards This feature meets the annunciations requirements in applications requiring NFPA 110 level one protection DC INTERCONNECTIONS TO THE ATS WARNING Be sure Engine Generator is in the OFF p...

Страница 12: ...RESET button pressed to reset the module The icon will be flashing in the display SELECTING THE CORRECT VOLTAGE A variety of three phase voltages are available from the three position selector switch...

Страница 13: ...come on Note There is no start delay in this mode of operation 2 Press and release the green START ENGINE button The DSE 7310 MKII will send a start signal to the ECU on the engine The engine ECU wil...

Страница 14: ...ning light Simply reset the ATS start over Once you have completed testing of the ATS be sure you ALWAYS leave the system in the standby mode unless servicing the unit For standby operation press the...

Страница 15: ...tween these to leads must be between 190 264 Center tapped on 480 Volt LED Indicator Light FITTING AND OPERATING 2006 3 TD_AS440 AVR_03 09_04_GB SUMMARY OF AVR CONTROLS CONTROL FUNCTION DIRECTION VOLT...

Страница 16: ...HHN THHW THW 2 XHH XHHW XHHW 2 ZW 2 SIZE AWG OR KCMIL Wire Type RHW THHW THW THWN XHHW USE Wire Type TBS SA SIS THHN THW 2 THWN 2 RHH RHW 2 USE 2 XHH XHHW XHHW 2 ZW 2 44 57 75 88 101 114 132 154 176 2...

Страница 17: ...17 OPM 115 REV A SELECTOR SWITCH WIRING DIAGRAM DX90 DX130...

Страница 18: ...18 OPM 115 REV A DX175...

Страница 19: ...19 OPM 115 REV A DX250...

Страница 20: ...20 OPM 115 REV A DX90F4 DX130F4 DSE 7310 MKII WIRING DIAGRAM...

Страница 21: ...57 67 57 1 1 77 77 1 5 7 50 1 2 6 211 725 211 725 66 86 86 86 86 86 36 4 25 46 53354 6 5 1 1 6 5 1 1 1 1 1 36 32 5 6 7 66 0 5 1 6723 6 7 9 5 92 7 8670 17 5 267 7 9 5 4 88 4 2 22 17 02 8 7 50 1 2 803...

Страница 22: ...AND LOW WYE THREE PHASE LOW WYE 120 208 VOLTS THREE PHASE HIGH WYE 277 480 VOLTS THREE PHASE HIGH WYE 277 480V THREE PHASE LOW WYE 120 208V THREE PHASE DELTA 120 240 VOLTS THREE PHASE AC WIRING DELTA...

Страница 23: ...23 OPM 115 REV A ENGINE WIRING HARNESS DX90F4 DX130F4 DX175F4 DX350F4...

Страница 24: ...or 1000 hours which ever occurs first from date of purchase In no event is WINCO liable for incidental or consequential damages Note Some states do not allow limitation on the duration of implied warr...

Отзывы: