Check the Setup Program menus to be sure that the port is enabled. If the port is not enabled,
the WinBook FX will not communicate with external devices connected to the port. To
enable the Communications Port, follow these steps:
Enter the Setup Program (see "Check the Setup Program Settings" under Fast Fixes).
Select
Advanced
menu.
Enable
External COM port
for
COM1
.
Save the new setup and leave the setup program (see "Check the Setup Program
Settings" under Fast Fixes).
Your cable may be broken or you may have the wrong kind of [FX 10-39] cable. If so,
the WinBook FX will not be able to communicate with external devices. Try replacing
the cable.
INTERNAL MODEM DOESN’T WORK
The WinBook FX’s internal modem doesn’t work.
Check the software application that you use for communicating. This application chooses the
Communications Port for your modem. Sometimes communications applications
automatically look for the modem and adjust this setting. Sometimes you need to choose this
setting for the application. If you need to make this choice manually, you should choose
COM3 for either PCMCIA or internal modems.
SERIAL INFRARED PORT DOESN’T WORK
I can’t get my Serial Infrared Port to work properly.
Go into the Setup Program and make sure the infrared port is enabled on COM2. If you are
using Windows 95, also check that the Setup Program is set to the "Plug and Play OS" mode.
You must line up the external device correctly. The Serial Infrared Port used infrared light to
communicate with external devices. To use the port, you must have an unobstructed visual
pathway between the WinBook FX’s serial infrared transceiver and the external device’s
serial infrared transceiver. If the line of sight between the transceivers is blocked,
communication between the devices will stop. The WinBook FX and the eternal device can
be up to 1 meter apart with a 15º angle.
Make sure that the transceiver windows on each device are clean. Finger prints or dust
buildup may obstruct the line of sight between the devices.[FX 10-40]
Take advantage of the Puma TranXit documentation and on-line help feature.
To use the Serial Infrared Port, you may need to enable the port. Se Check the Setup Program
Settings" under Fast Fixes for instructions on entering and leaving the Setup Program.
Enter the Setup Program
Select
Advanced
menu.
Set
IR port
to
COM2
.
Leave the Setup Program.
PRINTER PORT
Содержание FX
Страница 26: ...FX Chapter 3 ...
Страница 123: ......