Installation and operating instructions Wilo-Rexa PRO 15
PRODUCT DESCRIPTION
US English
3.4.2.
Operating mode S2 (short term operation)
The maximum operating period is specified in
minutes, e.g. S2-15. The pause must last until the
machine temperature is no more than 2 K away from
the temperature of the coolant.
3.4.3.
Operating mode S3 (intermittent operation)
This operating mode defines a combination of pe
-
riods of operation and standstill. With S3 operation,
the values given are always calculated based on a
period of 10 minutes.
Example: S3 25 %
Operating time 25 % of 10 min = 2.5 min / standstill
time 75 % of 10 min = 7.5 min
3.4.4. "Non-immersed operation" operating mode
The "non-immersed operation" operating mode de-
scribes the possibility of the motor emerging during
the drainage pumping sequence in a wet well instal-
lation, which enables a further lowering of the water
level as far as the upper edge of the hydraulics.
During non-immersed operation, the medium
and ambient temperature must not exceed 104 °F
(40 °C).
•
P 13 motor:
Non-immersed operation is permis-
sible in accordance with the specification "Non-
immersed operating mode" on the rating plate.
•
P 17 motor:
Non-immersed operation is not per-
mitted!
3.5. Technical data
* S1 operation when non-immersed is
not
possible
with all motors. Observe the information on the
rating plate.
** Operating mode S3 50% is permissible if the
necessary motor cooling is guaranteed by complete
immersion for at least 1 minute before the motor is
switched back on again.
The specified technical data apply to the standard
pumps in the PRO series.
The technical data for freely configured pumps in
the PRO series can be found in the relevant order
confirmation.
General data
Line power [V/F]:
See rating plate
Power consumption [P
1
]:
See rating plate
Rated motor power [P
2
]:
See rating plate
Maximum delivery head [H]:
See rating plate
Maximum volume flow [Q]:
See rating plate
Activation type [AT]:
See rating plate
Fluid temperature [t]:
37…104 °F (3…40 °C)
Protection class:
IP 68 (permanently im-
mersed)
Insulation class [Cl.]:
F (optionally H)
Speed [n]:
See rating plate
Max. immersion depth:
66 ft (20 m)
Explosion protection:
FM
Operating modes
Immersed [OT
S
]:
S1
Non-immersed [OT
E
]:
- P 13 motor:
S1*, S2 30min, S3 25%**
- P 17 motor:
-
Switching frequency
Recommended:
20 /h
Maximum:
50 /h
Free ball passage
PRO V05-…:
2 in (50 mm)
PRO V06-…:
2.5 in (65 mm)
PRO V08-…:
3 in (80 mm)
PRO C05-…:
1.8 in (45 mm)
PRO C06-…:
1.8 in (45 mm)
PRO C08-41…:
2.6 in (65 mm)
PRO C08-43…:
2.8 in (70 mm)
PRO C10-51…:
4 in (100 mm)
Suction connection:
PRO …05-…:
DN 50, PN 10
PRO …06-…:
DN 65, PN 10
PRO …08-…:
DN 80, PN 10
PRO …10-…:
DN 100, PN 10
Pressure connection:
PRO …05-…:
ANSI B16.1 125lbs 2
PRO …06-…:
ANSI B16.1 125lbs 2.5/3
PRO …08-…:
ANSI B16.1 125lbs 3
PRO …10-…:
ANSI B16.1 125lbs 4