Leakages
Observe local standards and regulations. Avoid pump leakages to protect persons and the
environment against hazardous (explosive, toxic or hot) substances.
Ensure that a dry run of the pump is not possible. A dry run can damage the shaft seal and
thereby cause leakages.
2.7
Maintenance tasks
ƒ
Wear the following protective equipment:
–
Sealed safety goggles
–
Safety shoes
–
Safety gloves for protection against cuts
ƒ
Only carry out the maintenance tasks described in these installation and operating in-
structions.
ƒ
Only original parts from the manufacturer may be used for maintenance and repairs. Use
of parts other than original parts releases the manufacturer from any liability.
ƒ
Collect any leakage of fluid and operating fluid immediately and dispose of it according
to the locally applicable guidelines.
ƒ
Store tools at the designated locations.
ƒ
After completing work, reattach all safety and monitoring devices and check that they
function properly.
2.8
Drive: NEMA standard motor
The hydraulics have a standardized connection flange for installing a NEMA standard motor.
See the technical data for the performance data (e.g. size, construction, hydraulic rated
power, speed) needed to select a motor.
2.9
Operator responsibilities
The operator must:
ƒ
Provide the installation and operating instructions in a language which the personnel can
understand.
ƒ
Make sure that personnel are suitably trained for the specified work.
ƒ
Ensure that safety and information signs mounted on the device are always legible.
ƒ
Train personnel with regard to the operating principles of the system.
ƒ
Eliminate any risk from electrical current.
ƒ
Equip hazardous components (extremely cold, extremely hot, rotating, etc.) with an on-
site guard.
ƒ
Demarcate and cordon off the hazardous area.
ƒ
Define personnel responsibilities to ensure safe working practice.
Children and persons younger than 16 years or with reduced physical, sensory or mental ca-
pacities or limited experience are prohibited from handling the device! Persons under the
age of 18 must be supervised by a technician.
3
Application/use
3.1
Intended use
The glanded pumps in the Wilo NL-HE series are intended for use as circulators in building
services.
The Wilo NL-HE pumps may only be used for:
ƒ
Hot-water heating systems
ƒ
Cooling and cold water circulation systems
ƒ
Drinking water systems (special version)
ƒ
Industrial circulation systems
ƒ
Heat carrier circuits
ƒ
Irrigation
The pumps are only approved for the fluids specified in the “Technical data” section.