![Wilo NL-HE Series Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/wilo/nl-he-series/nl-he-series_installation-and-operating-instructions-manual_983192028.webp)
en
Commissioning
28
WILO USA 2021-01
ƒ
Filling and ventilation lines are closed.
ƒ
The motor is turning in the right direction.
ƒ
The coupling guard is attached correctly and is screwed tightly.
ƒ
Pressure gauges with a suitable measurement range are installed on the suction and
pressure side of the pump. Do not install the pressure gauges on the bends in the piping.
The kinetic energy of the fluid can affect the measured values at these points.
ƒ
All blind flanges are removed.
ƒ
The shut-off device on the suction side of the pump is completely opened.
ƒ
The shut-off device in the pressure pipe of the pump is completely closed or only slightly
opened.
WARNING
Risk of injury due to high system pressure!
The power and status of the installed centrifugal pumps must be constantly monitored.
• Do
not
connect pressure gauges to a pressurised pump.
• Install pressure gauges on the suction and pressure side.
NOTICE
It is recommended to attach a flow meter to determine the exact pump delivery rate.
CAUTION
Risk of property damage due to motor overload!
• To start up the pump, use the soft start, star-delta connection or speed control.
ƒ
Switch on the pump.
ƒ
After reaching the speed, slowly open the shut-off device in the pressure pipe and regu-
late the pump to the duty point.
ƒ
While the pump is starting, vent completely via the venting screw.
CAUTION
Risk of property damage!
If abnormal noises, vibrations, temperatures or leaks occur when starting up:
• Switch the pump off immediately and remedy the cause.
7.5
Switching frequency
CAUTION
Risk of property damage!
The pump or motors may be damaged by incorrect switching.
• Only switch on the pump again when the motor is at a complete standstill.
A maximum of 6 connections per hour are permitted in accordance with IEC 60034-1. It is
recommended that repeated activations occur at regular intervals.
Содержание NL-HE Series
Страница 1: ...Pioneering for You Wilo NL HE 3327453 Ed 01 2021 01 en Installation and operating instructions ...
Страница 2: ......
Страница 42: ......
Страница 43: ......