Installation and electrical connection
en
Installation and operating instructions Wilo NL-HE
19
ƒ
Before pouring concrete or grout create an enclosed frame around the base.
ƒ
After curing, check the anchor bolts for a tight fit.
ƒ
Coat the unprotected surfaces of the base to protect from moisture.
6.6
Pipework
The pipe connections of the pump are fitted with dust caps so that no foreign objects can
penetrate during transport and installation.
ƒ
These caps must be removed before connecting pipes.
r
5 x DN
d
s
r ≈ 2,5 · (d - 2s)
Fig. 10:
Connecting the pump without tension,
settling section upstream and downstream of
the pump
CAUTION
Improper pipework/installation can lead to property damage! Welding beads,
cinder and other contaminants can damage the pump!
• The pipes must be sufficiently dimensioned, taking the pump inlet pressure into ac-
count.
• Connect the pump and pipes using suitable gaskets. Take the pressure, temperature
and fluid into account. Check the gaskets for proper fitting.
• The pipes must not transfer any forces to the pump. Brace the pipes directly before the
pump and connect them without tension.
• Observe the permissible forces and torques on the pump connecting pieces!
• The expansion of the pipes in the event of a temperature rise is to be compensated by
suitable means.
• Avoid air pockets in piping by means of appropriate installations.
NOTICE
Simplify subsequent work on the unit!
• To ensure the entire unit does not have to be emptied, install a check valve and
shut-off devices before and after the pump.
NOTICE
Avoid flow cavitation!
• A settling section must be provided upstream and downstream of the pump in the
form of a straight pipe. The length of the settling section must be at least 5 times
the nominal diameter of the pump flange.
ƒ
The pipes and pump must be free of mechanical stress when installed.
ƒ
The pipes must be fixed in such a way that the pump does not have to support the
weight of the pipes.
ƒ
Clean, flush and purge the unit before connecting the pipes.