en
Maintenance/repair
32
WILO USA 2021-01
9.5
Dismantling
DANGER
Risk of fatal injury due to electrical current!
Improper conduct when carrying out electrical work can lead to death due to electric
shock!
• Any work on electrical devices may only be carried out by a qualified electrician.
• Before all work on the unit, deactivate the power supply and guard against acci-
dental switch-on.
• Any damage to the pump connection cable should only ever be rectified by a quali-
fied electrician.
• Observe the installation and operating instructions for the pump, motor and other
accessories.
• Reinstall any uninstalled safety devices, such as terminal box covers, once the work
is complete.
Maintenance and repair work require the pump be partially or completely dismantled. The
pump housing can be installed in the piping.
ƒ
Switch off the energy supply to the pump and secure against switching on again.
ƒ
Close all valves in the suction line and pressure pipe.
ƒ
Drain the pump by opening the drainage screw and the venting screw.
ƒ
Remove coupling guard.
ƒ
If present: Remove the intermediate sleeve of the coupling.
ƒ
Remove the fastening screws of the motor from the baseplate.
NOTICE
Observe the section drawing in the chapter “Spare parts”.
9.5.1
Dismantling the slide-in unit
1.1
1.2
14
Fig. 18:
Removing the slide-in unit