en
Maintenance/repair
34
WILO USA 2021-01
9.5.2
Dismantling the bearing bracket
4.5 4.3 4.2 4.4
5
4.4 4.2
4.3 3.3
8.1 8.3 8.2
Fig. 22:
Bearing bracket
4.1A
4.1B
3.1
Fig. 23:
Shaft
1. Remove the key (3.3).
2. Pull off the thrower (4.5) and V-gaskets (4.3).
3. Remove the bearing cover (4.2) and retaining ring (4.4).
4. Loosen the hexagon head screw (8.2), remove the lock washer (8.3) and remove the
pump support foot (8.1).
5. Completely remove the shaft (3.1) from the bearing bracket (5).
6. Remove the ball bearings (4.1A and 4.1B) from the shaft (3.1).
9.6
Installation
Installation must be carried out according to the detailed drawings in the “Dismantling”
chapter and the general drawings in the “Spare parts” chapter.
ƒ
Clean the single components and check them for wear before installing them. Damaged
or worn parts must be replaced with original spare parts.
ƒ
Coat location points with graphite or similar materials before installation.
ƒ
Check the O-rings for damage and replace if necessary.
ƒ
Flat gaskets must be constantly replaced.
DANGER
Risk of fatal injury due to electrical current!
Proceeding incorrectly when carrying out electrical work can lead to death by electric
shock!
• Any work on electrical devices may only be carried out by a qualified electrician.
• Before all work on the unit, deactivate the power supply and secure it against being
accidentally switched on again.
• Any damage to the pump connection cable should only ever be repaired by a quali-
fied electrician.
• Observe the installation and operating instructions for the pump, motor and other
accessories!
• Reinstall any uninstalled safety devices, such as terminal box covers, once the work
is complete!