English

Installation and operating instructions Wilo-MVI 10, 15, 30, 50, 80

5

Outline and pipe dimensions:

See fig. 3a - d

5.3 Scope of Supply 

• Installation and operating instructions
• Flanges: 

-

Oval two bolt style: companion flanges, bolts 
and gaskets are included with the pump.

-

ANSI 300lb: pump delivered with gaskets and 
bolts without counter-flanges (accessories as 
option),

-

Victaulic type with rapid hose coupling for Vic-
taulic bracket: pump delivered without brackets 
(accessories as option).

5.4 Accessories 

• By-pass kit
• Counter Flanges (300 # round type, various connec-

tions and Oval 2 bolt threaded)

6 Description and function

6.1 Product description (see fig. 1 & 2)

1-Strainer-foot valve
2-Pump suction valve
3-Pump discharge valve
4-Non-return valve
5-Venting and filling plug
6-Drain-priming plug
7-Pipe supports
8-Strainer
9-Storage tank

10-Town water supply
11-Motor starter
12-Lifting hook
13-Foundation block
HA: Maximum suction head
HC: Minimum inlet pressure

6.2 Design of pump and motor

Vertical multistage in-line, glanded (with mechani-
cal seal) centrifugal pump.  Motor standard NEMA 
frame type, coupled to the pump with a shaft cou-
pling and coupling guards.

7 Installation and electrical connection

Installation and electrical work in compliance with 
any local codes and by qualified personnel only!

7.1 Installation

• The pump must be installed in a dry, well-ventilated 

and frost-free place.

• Install the pump in a dry place protected from frost 

and as close as possible to the water in a suction lift 
application.  

• Locate the pump in an accessible location to facili-

tate inspection and maintenance. The pump must be 
installed in a vertical configuration on a concrete 
base. 

• For especially heavy pumps, place a hook or a ring of 

sufficient capacity (total weight of pump) to allow 
the use of a hoist or similar device for the servicing 
and repair of the pump. 

• Install the pump on a concrete block (at least 4” / 10 

cm high).  Consider an vibration insulation pad 
between the concrete base and pump in locations 
where noise might cause problems.

• The installation surface must be level and flat: any 

tilting of the pump could cause premature bearing 
wear.  

5.2       Data table

Electrical data

Motor Enclosure:

ODP: Enclosure Type 1, for indoor use 
only
TEFC: Enclosure Type 2

Insulation class:

F

Frequency

60 Hz

Voltages

1

~

: 115/230 V (± 10 %)

3

~

: 208-230 V/460 V, 575 V  (± 10 %)

Others

Minimum suction 
head:

according to NPSH of the pump

Ambient humidity:

<90 %

Noise level

Depends on pump size, rotation speed, 
working point, motor type: it can reach 
77 dB(A) for ODP and 86 dB(A) for 
TEFC motors.

WARNING! Bodily injury
Existing regulations for the prevention of acci-
dents must be observed.

WARNING! Electrical shock hazard
Dangers caused by electrical energy must be 
excluded. 
National Electrical Codes, local codes and regula-
tions must be followed.

CAUTION! Possible damage of the pump
Dirt and solder drops into the pump body can 
effect the pump operation.

• It is recommended that any welding and soldering 

work be done before installing the pump.

• Thoroughly flush the system out before installing 

the pump.

WARNING! Risk of accident by hot surfaces
The pump must be positioned so that someone 
cannot come into contact with the hot pump sur-
faces while operation.

Содержание MVI 10

Страница 1: ...2 065 409 Ed 01 2006 10 GRD Wilo MVI 10 15 30 50 80 GB Installation and operating instructions F Notice de montage et de mise en service E Instrucciones de instalaci n y funcionamiento...

Страница 2: ...50 2 15 16 75 7 1 16 8 5 16 180 212 3 15 16 100 3 4 19 DN 32 13 16 20 DN 1 1 4 4 X 1 2 4 X 12 Fig 3b MVI 10 15 NPT 1 MVI 30 NPT 1 1 4 4 X 12 4 X 1 2 MVI 10 15 NPT 1 MVI 30 NPT 1 1 4 37 8 98 4 6 3 16 1...

Страница 3: ...8 X 3 4 8 X 19 5 127 Fig 3d MVI 50 NPT 1 1 2 MVI 80 NPT 2 80 130 187 250 4 X 12 20 100 215 252 4 X 12 20 100 215 252 MVI 80 NPT 2 3 15 16 8 7 16 9 15 16 13 16 NPT 2 4 X 1 2 MVI 50 NPT 1 1 2 3 1 8 5 1...

Страница 4: ...ge 12 4 Utilisation pr vue Application 12 5 Donn es techniques 12 6 Description et fonctionnement 13 7 Installation et raccordement lectrique 13 8 D marrage 15 9 Entretien et r paration 17 10 D fauts...

Страница 5: ...claims In particular failure to comply with these safety pre cautions could increase the possibility of the follow ing risks the failure of important parts of the pump or instal lation personal injury...

Страница 6: ...inal flow in GPM at 60Hz 2 poles 02 number of stages 1 Number of reduced impellers 1 1 stainless steel 304 2 stainless steel 316L 3 pump casing cast iron cataphoresis coated volute 304 stainless steel...

Страница 7: ...pplication Locate the pump in an accessible location to facili tateinspection andmaintenance Thepumpmustbe installed in a vertical configuration on a concrete base For especially heavy pumps place a h...

Страница 8: ...tion losses Connections have to be correctly sealed No air entrance is allowed on the suction pipe 2 See figure 1 7 3 Electrical connection The electrical characteristics frequency voltage nominal cur...

Страница 9: ...tion system Air evacuation process with pump under pressure see fig 2 Close the discharge valve 3 Open the venting plug 5 and the suction valve 2 and completely fill the pump Close the venting plug on...

Страница 10: ...en wait 20 seconds to allow air to settle Start again the pump If necessary particularly if the suction height exceeds 16 ft 5 m repeat these operations If water leaks at draining plug it means the pu...

Страница 11: ...motor is too low a Dismantle the pump and clean it b Clean all the pipes c Check tightness of the whole pipe up to the pump and make it tight d Fill the pump to prime again Check foot valve is tight e...

Страница 12: ...AG 10 2006 11 Spare parts All spare parts must be ordered through your local specialist and or Wilo Customer Services In order to avoid returns and incorrect orders please specify the name plate data...

Страница 13: ...rit peut accro tre la probabilit des risques suivants d faillance de fonctions importantes de la pompe ou de l installation dangers pour les personnes par influences lectri ques ou m caniques dommages...

Страница 14: ...sque vous la manipulez afin d viter qu elle ne bascule et ne tombe ATTENTION Risque d endommager la pompe Ces pompes conviennent uniquement au refoulement de l eau Exemple MVI220 02 1 1 A3 E80 3 575 1...

Страница 15: ...Installation La pompe doit tre mont e dans un endroit sec bien a r et l abri du gel 5 2 Tableau de donn es Pressions de service Corps de pompe Bride Ovale 230 PSI 16 bars Brides ANSI 300lb 360 PSI 25...

Страница 16: ...vider et remplir de nouveau le sys t me si la pompe doit tre remplac e Il est recommend que le tuyau menant au c t aspiration de la pompe ait un longueur qui est le tri ple du diam tre du tuyau Il co...

Страница 17: ...t le moteur Il devra tre connect au moteur avec un c ble de longueur mini male blind si n cessaire 8 D marrage 8 1 Rin age pr liminaire 8 2 Remplissage et d gazage du syst me Deux cas types Fig 1 Cas...

Страница 18: ...recommandons sa protection par un pressostat ou un interrupteur flotteur 8 3 Contr le du sens de rotation Avant de d marrer la pompe assurer que les l ments rotatifs ne sont pas coinc s Retirer soit...

Страница 19: ...ent recommand de graisser l extr mit de l arbre moteur ainsi que l al sage de l accouplement avec une graisse forte adh rence type D321R Molikote ou 8191 Loctite par exemple chaque montage ou remontag...

Страница 20: ...e la pompe instal l e et de l installation f Contr ler la tension aux bornes du moteur et la bonne sec tion des conducteurs 2 La pompe vibre a Mal serr e sur son socle b Corps trangers obstruant la po...

Страница 21: ...entre otros los siguientes da os fallos en funciones importantes de la bomba o el sis tema lesiones personales debidas a causas el ctricas mec nicas o bacteriol gicas da os materiales 2 4 Instruccion...

Страница 22: ...enimiento para evitar que la bomba se caiga y pueda poner en peligro la seguridad de las per sonas ATENCI N Peligro de da ar la bomba Estas bombas s lo son tiles para impulsar agua Ejemplo MVI220 02 1...

Страница 23: ...lado al motor mediante un eje y protecciones 7 Instalaci n y conexi n el ctrica S lo personal cualificado de acuerdo con la norma tiva vigente local podr efectuar los trabajos de instalaci n y el ctri...

Страница 24: ...ber a que lleva al lado de aspiraci n de la bomba tiene una longitud m nima que sea tres veces m s larga que el di metro de tuber as Aconsejamos prever una v lvula de retenci n en el tubo de impulsi n...

Страница 25: ...dor entre el conver tidor y el motor Dicho filtro tendr que conectarse al motor con un cable de longitud m nima y si es pre ciso blindado 8 Arranque 8 1 Limpieza preliminar 8 2 Llenado y purgado del s...

Страница 26: ...interruptor de flotador 8 3 Confirme rotaci n correcta Antes de arrancar la bomba aseg rese de que los elementos rotatorios est n carente de cualquier tipo de obstrucci n Retire o uno o ambos protecto...

Страница 27: ...a su vida til por lo que no es preciso engrasarlo Recomendamos que lubrique el motor del eje as como el orificio de acoplamiento con una grasa de fuerte adherencia por ejemplo de tipo D321R Molikote o...

Страница 28: ...piraci n es demasiado elevada controlar el NPSH de la bomba instalada y de la instalaci n f Controle el voltaje en los bornes del motor y la secci n de los cables 2 La bomba vibra a Est mal ajustada a...

Страница 29: ...M BE KI7 BB9 Dehj j 7l C bhei FWha B KI7 F ed 0 M BE KI7 M_be 9WdWZW dY 8Wo j 7l D 9Wb Who 7bX hjW J 7 B 97D7 7 F ed 0 M BE 9 D 7N0 7N0...

Отзывы: