SM3BAT User Guide
Developing Custom Programs
page
51
BIOACOUSTIC MONITORING SYSTEMS
Message
Warning/Error
Explanation
microphones are connected.
HPF 16K, no
ult hw:
error
a RECORD command has been reached, an ultrasonic board
is not present, and the preceding HPF command has one
or both channels set to 16K.
HPF 16K,
acoust rate:
error
a RECORD command has been reached, the preceding FS
command rate parameter is less than 192k, and the
preceding HPF command has one or both channels set to
16K.
Bad ZC gain:
error
a RECORD command has been reached, an ultrasonic board
is present, the preceding ZC command has a channel
enabled (either explicitly at any time or via AUTO
selection at run time), and the preceding GAIN command
value for that channel is neither 0 nor 12 dB.
Bad FS ultra
gain:
error
a RECORD command has been reached, an ultrasonic board
is present, the preceding FS command has a channel
enabled (either explicitly at any time or via AUTO
selection at run time) and a rate greater than 96000,
and the preceding GAIN command value for that channel
is neither 0 nor 12 dB.
ZC, no ult
hw:
error
a RECORD command has been reached, an ultrasonic
SM3BAT recorder is not present, and the preceding ZC
command Channel parameter is not OFF.
ZC acoust mic
no FS:
run-time
warning
a RECORD command has been reached, an ultrasonic board
is present, the preceding ZC command has a channel
enabled (either explicitly or via AUTO selection) and
the preceding FS command does not have that same
channel enabled (either explicitly or via AUTO
selection), and an external acoustic microphone is
attached to that channel.
Ultra mic no
ultr hw:
run-time
warning
a RECORD command has been reached, an ultrasonic
device is not present, the preceding FS command
Channel parameter is not OFF and its rate parameter is
AUTO, and at least one external ultrasonic microphone
is connected.
Ext acst &
ultr mics:
run-time
warning
a RECORD command has been reached, the preceding FS
command Channel parameter is not OFF and its rate
parameter is AUTO, and an external ultrasonic
microphone is connected to one channel and an external
acoustic microphone is connected to the other channel.
Can't open
play file:
run-time
error
a PLAY command has been reached and there is a failure
accessing the SD card in slot A or a failure opening
the desired file on the card.
Содержание sm3bat
Страница 6: ......
Страница 71: ...SM3BAT User Guide SM3BAT Specifications page 65 BIOACOUSTIC MONITORING SYSTEMS ...
Страница 75: ...SM3BAT User Guide SM3BAT Specifications page 69 BIOACOUSTIC MONITORING SYSTEMS ...
Страница 76: ...SM3BAT Specifications SM3BAT User Guide page 70 BIOACOUSTIC MONITORING SYSTEMS ...
Страница 77: ...SM3BAT User Guide SM3BAT Specifications page 71 BIOACOUSTIC MONITORING SYSTEMS ...