Developing Custom Programs
SM3BAT User Guide
page
50
BIOACOUSTIC MONITORING SYSTEMS
Message
Warning/Error
Explanation
triggered:
recording disabled.
Bad FS sample
rate:
error
a RECORD command has been reached and the preceding FS
command’s rate parameter does not have one of the
allowed values: OFF, AUTO, 1000, 2000, 4000, 8000,
9600, 12000, 16000, 19200, 24000, 32000, 48000, 96000,
192K, 256K, 384K
No record
channels:
error
a RECORD command has been reached and the preceding FS
and ZC commands’ channel parameters are all OFF.
ZC not
triggered:
error
a RECORD command has been reached, the preceding ZC
command’s channel parameter is not OFF, and triggered
recording is not enabled.
Ult rate, no
ult hw:
error
a RECORD command has been reached, the preceding FS
command’s channel parameter is not OFF, and its rate
parameter is greater than or equal to 192K.
Using only
channel 0:
run-time
warning
a RECORD command has been reached, an ultrasonic board
is present, the preceding FS command’s channel
parameter is AUTO, there are two external microphones,
and the preceding FS command’s rate parameter is set
too high for stereo for the command’s file type (WAV,
WAC): the recorder will choose one channel to use
rather than stereo, choosing whichever channel has an
ultrasonic microphone or channel 0 if they both have
ultrasonic microphones.
Using only
channel 1:
run-time
warning
a RECORD command has been reached, an ultrasonic board
is present, the preceding FS command’s channel
parameter is AUTO, there are two external microphones,
and the preceding FS command’s rate parameter is set
too high for stereo for the command’s file type (WAV,
WAC): the recorder will choose one channel to use
rather than stereo, choosing whichever channel has an
ultrasonic microphone or channel 1 if they both have
ultrasonic microphones.
Bad rate for
stereo:
error
a RECORD command has been reached and the preceding FS
command’s channel parameter is 0+1 (stereo) and its
rate parameter is set too high for its file type (WAV,
WAC).
No
microphones:
run-time
error
a RECORD command has been reached, an ultrasonic board
is present, and there are no external microphones
attached.
Missing
microphone:
run-time
warning
a RECORD command has been reached, an ultrasonic board
is present, and there is no external microphone on a
channel explicitly selected (0, 1, or 0+1; not AUTO or
OFF) in the preceding FS or ZC command.
No ultra
microphones:
run-time
warning
a RECORD command has been reached, the preceding FS
command’s channel parameter is not OFF, its rate
parameter is 192k or greater, and only external
acoustic microphones are connected.
Acous rate
ultr mics:
run-time
warning
a RECORD command has been reached, the preceding FS
command’s channel parameter is not OFF, its rate
parameter is less than 96000, and only ultrasonic
Содержание sm3bat
Страница 6: ......
Страница 71: ...SM3BAT User Guide SM3BAT Specifications page 65 BIOACOUSTIC MONITORING SYSTEMS ...
Страница 75: ...SM3BAT User Guide SM3BAT Specifications page 69 BIOACOUSTIC MONITORING SYSTEMS ...
Страница 76: ...SM3BAT Specifications SM3BAT User Guide page 70 BIOACOUSTIC MONITORING SYSTEMS ...
Страница 77: ...SM3BAT User Guide SM3BAT Specifications page 71 BIOACOUSTIC MONITORING SYSTEMS ...