SM3BAT User Guide
Developing Custom Programs
page
49
BIOACOUSTIC MONITORING SYSTEMS
one or more
errors
, it will not run. To resolve an error, edit the program and adjust
a parameter or add, move, or delete a command line. Refer to the following list of
the most common possible program warnings and errors.
SM3BAT Program Errors and Warnings
Message
Warning/Error
Explanation
Unmatched
REPEAT:
error
a REPEAT command for which no corresponding subsequent
UNT_X command can be found.
Unmatched
UNTX:
error
an UNT_X command for which no corresponding preceding
REPEAT command can be found.
Inf lp bfr
REC/PLAY:
error
the program has an infinite loop before reaching any
RECORD or PLAY command.
Unreachable
command:
warning the program has commands following an infinite loop.
No RECORD or
PLAY:
error
the program contains neither a RECORD nor a PLAY
command.
No HPF cmd:
error
a RECORD command has been reached with no preceding
HPF command.
No GAIN cmd:
error
a RECORD command has been reached with no preceding
GAIN command.
No FS cmd:
error
a RECORD command has been reached with no preceding FS
command.
No ZC cmd:
error
a RECORD command has been reached with no preceding ZC
command.
No DTRGLVL
cmd:
error
a RECORD command has been reached with no preceding
DTRGLVL command.
No FREQMIN
cmd:
error
a RECORD command has been reached, with triggered
recording enabled, with no preceding FREQMIN command.
No FREQMAX
cmd:
error
a RECORD command has been reached, with triggered
recording enabled, with no preceding FREQMAX command
No DURMIN
cmd:
error
a RECORD command has been reached, with triggered
recording enabled, with no preceding DURMIN command
No DURMAX
cmd:
error
a RECORD command has been reached, with triggered
recording enabled, with no preceding DURMAX command
No DTRGWINDOW
cmd:
error
a RECORD command has been reached, with triggered
recording enabled, with no preceding DTRGWINDOW
command
No DTRGMAXLEN
cmd:
error
a RECORD command has been reached, with triggered
recording enabled, with no preceding DTRGMAXLEN
command
FREQMAX <=
FREQMIN:
error
a RECORD command has been reached, and a channel’s
preceding FREQMAX value is less than or equal to its
preceding FREQMIN value.
DURMAX <=
DURMIN:
error
a RECORD command has been reached, and a channel’s
preceding DURMAX value is less than or equal to its
preceding DURMIN value.
Nap not
warning a NAP command has been reached with triggered
Содержание sm3bat
Страница 6: ......
Страница 71: ...SM3BAT User Guide SM3BAT Specifications page 65 BIOACOUSTIC MONITORING SYSTEMS ...
Страница 75: ...SM3BAT User Guide SM3BAT Specifications page 69 BIOACOUSTIC MONITORING SYSTEMS ...
Страница 76: ...SM3BAT Specifications SM3BAT User Guide page 70 BIOACOUSTIC MONITORING SYSTEMS ...