Configuration
60
Version 1.0 Rev B - 08/00
7.
Press
Enter
. The change is saved when
appears beside the confirmation
field.
Setting Remote Access
The Hopper Plus can be accessed and configured via the Ethernet and over the RF link.
The default setting is to allow both forms of remote access, but they can be disabled if
required (as a security measure, for example).
To set Ethernet and wireless access
1.
From the Main Menu, select
System Security
. The System Security
window is
displayed.
2.
Select
Ethernet Access to Local Host
.
3.
In the Ethernet Access to Local Host field, select the desired setting.
4.
Press
Enter
.
5.
Select
Wireless Access to Local Host
.
6.
Select the desired setting.
7.
Press
Enter
.
on
Enable access to the unit via the Ethernet.
off
Disable access to the unit via the Ethernet.
on
Enable access to the unit via the air.
off
Disable access to the unit via the air.
Success
System Security
SNMP Community Name 1 public
SNMP Community Name 2 netman
Change User Password Press Enter to change password
Confirm User Password Press Enter to confirm password
Change Supervisor Password Press Enter to change password
Confirm Supervisor Password Press Enter to confirm password
Ethernet Access to Local Host -> on
Wireless Access to Local Host on
Auto Logout Minutes (1-120) 10