Configuration
36
Version 1.0 Rev B - 08/00
Setting the Link Monitor Period
The Link Monitor Period determines the amount of test data that is sent during a link
monitor test. The following table shows how much test data is sent during the link monitor
test.
To set Link Monitor Period
1.
From the Main Menu
,
select
RF Station Configuration
. The RF Station
Configuration window is displayed.
2.
Select
Link Monitor Period
.
3.
Type the time value in minutes (0=OFF, 1-1000)
4.
Press
Enter
.
Monitor
Setting
Test data (%)
Message data (%)
Notes
0
0
100
link monitor disabled
1
50
50
maximum test data
2
33.3
66.6
3
25
75
. . .
. . .
. . .
10000
0.01
99.99
minimum test data
RF Station Configuration
Operating Mode Normal Mode
RF Transmit Status unblocked
Link Monitor Period (0=OFF, 1-10000) ->10
Test Mode Timer Minutes (1-1000) 5
Base Station Only Parameters
Maximum Remote Distance 5 Km
Link Monitor Remote Station Rank 1
Remote Station Only Parameters
Throttle Enable off
Throttle Level (1-50) 1