7. Starting, operation
GB
Load (e.g. display)
Power supply
UB+/Sig+
Positive supply / measurement connection
OV/Sig-
Negative supply / measurement connection
Circular connector
M 12x1,
IP 67
Order code: M4
Flying leads
with 1.5 m of cable,
conducter cross section
up to max. 0.5 mm²,
AWG 20 with end splices,
conducter outer diameter
6.8 mm
IP 67
Order code: DL
L-Connector,
DIN EN 175301-803,
Form A
for conducter cross section
up to max. 1.5 mm²,
conducter outer diameter
6 to 8 mm
IP 65
Order code: A4
-wire
brown
green
With a line transformer you realise the mandatory galvanic isolation of the voltage
and current supply between hazardous and non-hazardous areas and ensure the
safety connection data.
Non hazardous
area
Hazardous
(classified) area
Non hazardous
area
Hazardous
(classified) area
Non hazardous
area
Hazardous
(classified) area
screen
Non hazardous
area
Hazardous
(classified) area
Non hazardous
area
Hazardous
(classified) area
Bayonet-connector,
IP 67
Order code: C6
Connector M16x0.75,
IP 65,
Order code: B5
(D) Mounting hole
1. Loosen the screw (1).
2. Loosen the cable gland (2).
3. Pull the angle housing (5), with the
terminal block (6) inside, away from the
instrument.
4. Using the head of a small screwdriver in
the mounting hole (D), lever the terminal
block (6) out of the angle housing (5).
In order not to damage the sealing of the angle housing, do not try to push the terminal
block (6) out using the screw hole (1) or the cable gland (2).
5. Ensure that the conductor outer diameter you select is matched to the angle housing’s
cable gland. Slide the cable through the cable gland nut (2), washer (3), gland seal (4) and
angle housing (5).
6. Connect the flying leads to the screw terminals on the terminal block (6) in accordance
with the pin-assignment drawing.
7. Press the terminal block (6) back into the angle housing (5).
8. Tighten the cable gland (2) around the cable. Make sure that the sealing isn’t damaged
and that the cable gland and seals are assembled correctly in order to ensure ingress
protection.
9. Place the flat, square gasket over the connection pins on the top of the instrument
housing.
10. Slide the terminal block (6) onto the connection pins.
11. Secure the angle housing (5) and terminal block (6) to the instrument with the screw (1).
Assembly of L-connector DIN EN 17501-80
(6)
(5)
(1)
(2)
(3)
(4)
Clamping nut,
Male connector,
Case with
pressure connection
Sealing
Female
connector