9.
Wieland Electric | BA000349 | 05.2007
9 |
Appendix
9 Appendix
9.
Technical data
Electronics supply
• Input voltage
24 VDC ± 20 % (19.2 V ... 28,8 V)
• Power consumption
approx. 2 W (without MOVIMOT)
• MOVIMOT power consumption
approx. 0.2 W
• MOVIMOT switch-on current
1 A
AC input voltage at X0
• Input voltage V
supply
230/400 VAC
• Supply frequency input
50 Hz ± 10 % (45 Hz ... 55 Hz)
AC output voltage at X
• Output voltage
V
supply
(input voltage)
• Output current per phase
max. 16 A
• Output frequency
50 Hz ± 10 % (45 Hz ... 55 Hz)
• Length of hybrid cable (load connection) max. 5 m
Digital inputs
• Digital inputs
X4 (IO 2, IO 3), X5 (I 0, I 1)
• Input current
typ. 5 mA
• Signal level V
high
/ V
low
+15 V ... +31,5 V / -3 V ... +5 V
• Initiator cable length
max. 5 m
Digital outputs
• Digital outputs
X4 (IO 2, IO 3)
• Voltage
24 VDC ± 20 %
• Current
1 A (total current O 2, O 3)
• Outputs (hybrid line)
RS485 interface, integrated bus termination;24 VDC
supply voltage, damping diode; L1, L2, L3 and PE,
cable length max. 5 m
PROFIBUS-DP
• PROFIBUS connection
DP-IN X3 (M12 plug)DP-OUT X2 (M12 socket)
• Transfer rate in kbaud
9.6 / 19.2 / 45.45 / 93.75 / 187.5 / 500 / 15000 / 3000
/ 6000 / 12000
• Address setting
max. 125 (set via rotary switches)
General data
• Environmental conditions (overall
system)
Industrial atmosphere
• Pollution degree
III
• Overvoltage category
3
• Fire behavior of contact carriers
min. UL94V2
• Temperature - operating environment
0...50 °C
• Temperature - storage/transport
-25 °C...60 °C / -25 °C...+70 °C
• Vibration
IEC 721 Class 3M6
• Air humidity
100 %, non-condensing
• Enclosure
IP 65 acc. to EN 60529
• Protection class
Class 1 acc. to IEC536
• Protection category
3
• Mounting position
any (preferably horizontal wall mounting)
• Dimensions W x H x L
see installation dimensions in chapter 2.8
Содержание podis MOT FP C
Страница 2: ......
Страница 22: ...Wieland Electric BA000349 05 2007 podis MOT FP C CM CP I IO RS485 SEW Device Description 2...
Страница 24: ...3 Wieland Electric BA000349 05 2007 Mechanical Installation Assembly 3...