8.
Wieland Electric | BA000349 | 05.2007
8 |
MOVILINK
®
Device Profile
8 MOVILINK
®
Device Profile
8.
Coding of process data
The same process data information is used across all fieldbus systems for the control and
setpoint input. The coding of the process data is carried out according to the uniform MOVIL-
INK profile for SEW drive inverters. For MOVIMOT, it is generally possible to differentiate the
following variants:
• Two process data words (2PD)
• Three process data words (3PD)
PO
Process output data
PI
Process input data
PO1 Control word
PI1
Status word 1
PO2 Speed (%)
PI2
Output current
PO3 Ramp
PI3
Status word 2
DO
Digital outputs
DI
Digital inputs
[ PO ]
PO1
PO2
PO3
PI1
PI2
PI3
[ PI ]
podis MOT also allows the additional connection of sensors and actuators at digital input and
output terminals via the two M12 sockets X4 and X5.
In the PROFIBUS-DP protocol, an additional I/O byte is attached after the process data for
MOVIMOT in which the additional digital inputs and outputs are mapped.
The coding is once again carried out according to the uniform MOVILINK profile for SEW
drive inverters.
[ PO ]
PO1
PO2
PO3
DO
PI1
PI2
PI3
DI
[ PI ]
To control MOVIMOT via two process data words (2PD), the process output data control word
and speed (%) are send from the higher-level automation device to MOVIMOT and the process
input data status word 1 and output current are transferred from MOVIMOT to the automation
device.
For control via three process data words, the ramp is transferred as additional process output
data word and status word 2 as the third process input data word.
Control via two
process data
words
Control via two
process data
words
Control via three
process data
words
Control via three
process data
words
Communication between podis
®
MOT and MOVIMOT
®
Communication between master and slave
Содержание podis MOT FP C
Страница 2: ......
Страница 22: ...Wieland Electric BA000349 05 2007 podis MOT FP C CM CP I IO RS485 SEW Device Description 2...
Страница 24: ...3 Wieland Electric BA000349 05 2007 Mechanical Installation Assembly 3...
Страница 44: ...5 Wieland Electric BA000349 05 2007 Commissioning 5...
Страница 46: ...6 Wieland Electric BA000349 05 2007 Operation 6...
Страница 62: ...9 6 Wieland Electric BA000349 05 2007 Appendix 9...
Страница 63: ......
Страница 64: ......