4.8
Wieland Electric | BA000349 | 05.2007
Electrical Installation
| 4
Pin Designation
Meaning
1 L1
Motor lead voltage U
2 L2
Motor lead voltage V
3 L3
Motor lead voltage W
4 0 V
0 V of external voltage(*)
5 +24 V
24 VDC of external voltage(*)
6 OUT 0
Supply for motor electronics
7 OUT 1
Motor control lead CW rotation
8 OUT 2
Motor control lead CCW rotation
9 OUT 3
Speed switching f1 / f2
10 IN 3
Ready message from motor
PE PE
PE connection
(*) The supply is provided by an external 24- V power supply.
DANGER
If the variant with industrial plug connector and revos MOT insert is selected, the
motor may be connected with the field distributor exclusively via an original Wieland
hybrid cable (see ordering notes/accessories on page 9.3). The use of other cables
may lead to life-threatening conditions.
If no plug connection is desired, it can also be placed directly on the terminals of the MOVI-
MOT.
The following assignment must be adhered to:
MOVIMOT
®
terminal Core designation
L1
L1 black
L2
L2 black
L3
L3 black
PE
green/yellow
⊥
(ground)
(-) 0 V white
+24 V DC
(+) 24 V red
RS+
+ RS485 orange
RS-
- RS485 green
(shield)
(shield)
Connection of
open cable end
Содержание podis MOT FP C
Страница 2: ......
Страница 22: ...Wieland Electric BA000349 05 2007 podis MOT FP C CM CP I IO RS485 SEW Device Description 2...
Страница 24: ...3 Wieland Electric BA000349 05 2007 Mechanical Installation Assembly 3...
Страница 44: ...5 Wieland Electric BA000349 05 2007 Commissioning 5...
Страница 46: ...6 Wieland Electric BA000349 05 2007 Operation 6...
Страница 62: ...9 6 Wieland Electric BA000349 05 2007 Appendix 9...
Страница 63: ......
Страница 64: ......