8.4
Wieland Electric | BA000349 | 05.2007
MOVILINK
®
Device Profile
| 8
If the process data exchange is carried out via three process data, the current integrator ramp
is transferred to MOVIMOT in the process output data word PA3.
If the process data exchange is carried out via two process data, the ramp set with switch
t1 is used.
Coding:
1 digit = 1 ms
Range:
100...10000 ms
Example:
2.0 s = 2000 ms = 2000dec = 07D0hex
Time [s]
Setting [ms]
Dec
Hex
0,5
500
1F4
1
1000
3E8
1,5
1500
5DC
2
2000
7D0
2,5
2500
9C4
3
3000
BB8
3,5
3500
DAC
4
4000
FA0
4,5
4500
1194
5
5000
1388
5,5
5500
157C
6
6000
1770
6,5
6500
1964
7
7000
1B58
7,5
7500
1D4C
8
8000
1F40
8,5
8500
2134
9
9000
2328
9,5
9500
251C
10
10000
2710
Calculation of
ramp times
Calculation of
ramp times