23340-2-1007
Page 35
the opposite end. Do not crimp or enlarge tube.
8. Attach the 4” (102mm) diameter flue outlet tube onto the rigid
venting system or directly to fireplace. Ensure the 4” (102mm)
diameter flue outlet tube is placed as far as possible onto the rigid
venting system. Mark the 4” (102mm) diameter flue outlet tube
2 1/2” (64mm) beyond the vinyl siding kit or wall. S
ee Figure
54.
Remove the 4” (102mm) diameter flue outlet tube from rigid
venting system. When installing directly to fireplace, tape gasket
needs to be used.
9. Mark or wrap tape completely around the tubes at the marked points
to help in making a true cut. Do not crimp or enlarge tubes.
10. From outside: Push the 6 5/8” (168mm) diameter inlet tube/mount-
ing plate onto end of rigid venting system to correct position. Fasten
the outside mounting plate to the vinyl siding kit or wall with (4)
10 x 1 1/2” screws. (Ensure upward slope).
11. From inside: Attach the inlet tube to the collar on the back of
the fireplace (or the rigid venting system) using (3) self tapping
screws.
12. Seal the 4” (102mm) diameter flue outlet tube. Follow instructions
and diagram (
Figure 56
).
13. Fasten 4” (102mm) diameter flue outlet tube in place. Do not “twist”
the flue outlet tube into the fireplace collar (or rigid venting sys-
tem). Hold the tube by the seam and push in using a perpendicular
“rocking” motion. This ensures the seam on the tube stay intact.
14. Fasten vent cap end using (3) 10 x 1/2” screws to mounting plate.
Sealing 4” (102mm) Diameter Flue Outlet Tube
7. Remove outside mounting plate with tube attached from wall. Mark
and cut the extra length of the 6 5/8” (168mm) diameter tube from
OUTSIDE WALL
MEASURE
VINYL SIDING KIT DV822
OUTSIDE MOUNTING
PLATE
EXT. WALL
SURFACE OR
VINYL SIDING KIT
FLUE
PIPE
CUT
2 ½”
BEYOND EXTERNAL
WALL SURFACE OR
VINYL SIDING KIT
Figure 54
Figure 55
1”
VENT CAP END
APPLY SEALANT
ON THE INSIDE
DO NOT PLACE
OVERLAPPED
SECTION OVER
THE SEAM IN THE TUBE
Figure 56
Note:
Tape gasket to be applied prior to installing to fireplace flue outlet tube
only. Tape gasket should not be used when mating the flue outlet tube to a rigid
venting system.
DVVK-4RE VENT KIT INSTALLATION INSTRUCTIONS (continued)
Содержание DVP36FP3 Series
Страница 43: ...23340 2 1007 Page 43 Figure 66 OPTIONAL THERMOSTAT OPTIONAL WALL SWITCH STANDING PILOT WIRING DIAGRAM ...
Страница 51: ...23340 2 1007 Page 51 INTERMITTENT PILOT TROUBLESHOOTING continued ...
Страница 55: ...23340 2 1007 Page 55 Figure 69 RF WIRING DIAGRAM ...
Страница 66: ...23340 2 1007 Page 66 SERVICE NOTES ...
Страница 67: ...23340 2 1007 Page 67 SERVICE NOTES ...