43
Drain System
The drain system can be installed using a floor drain, wall
standpipe, floor standpipe, or laundry tub. Select the method you
need.
IMPORTANT:
To avoid siphoning, no more than 4.5" (114 mm) of
drain hose should be inside standpipe or below the top of wash
tub. Secure drain hose with cable tie.
Floor standpipe drain system
Minimum diameter for a standpipe drain: 2" (51 mm). Minimum
carry-away capacity: 17 gallon (64 L) per minute. A 1/4" (6 mm)
diameter to 1" (25 mm) diameter Standpipe Adapter Kit is available
(Part Number 3363920). Top of standpipe must be at least 39"
(991 mm) from the floor; install no higher than 96" (2.44 m) from
bottom of machine. If you have an overhead sewer and need to
pump higher than 96" (2.44 m), a sump pump and associated
hardware are needed. See “Alternate parts.”
Wall standpipe drain system
See requirements in the “Floor standpipe drain system” section.
Laundry tub drain System
Minimum capacity: 20 gallon (76 L). Top of laundry tub must be at
least 39" (991 mm) from the floor; install no higher than 96" (2.44
m) from bottom of machine.
4.5"
(114 mm)
39"
(991 mm)
4.5"
(114 mm)
39
"
(991 mm)
minimum
4.5"
(114 mm)
39
"
(991 mm)
minimum
4.5"
(114 mm)
Floor Drain System
Floor drain system requires a Siphon Break Kit, two Connector
Kits, and an Extension Drain Hose that may be purchased
separately. Please contact your retailer for ordering information,
or see the “Assistance or Service” on Quick Start Guide. Minimum
siphon break height: 28" (710 mm) from bottom of machine.
(Additional hoses may be needed.)
Electrical Requirements
n
A 120 V, 60 Hz, AC only, 15 A or 20 A, fused electrical
supply is required. A time-delay fuse or circuit breaker is
recommended. It is recommended that a separate circuit
breaker serving only this appliance be provided.
n
This machine is equipped with a power supply cord having
a 3 prong grounding plug.
n
To minimize possible shock, the cord must be plugged
into a mating, 3 prong grounding-type outlet, grounded in
accordance with local codes and ordinances. If a mating
outlet is not available, it is the personal responsibility and
obligation of the customer to have the properly grounded
outlet installed by a qualified electrician.
n
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that the
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.