Bit 5 = Full
1 = All amps/drivers pass, 0 = 1 or more amps/drivers fail
Bit 6 = Partial
1 = 1 or more amps/drivers pass, 0 = all amps/drivers fail
Bit 7 = Bias
1 = Bias line is good, 0 = Bias line failure
The Active Status command (3FH) response is defined as follows:
Active Command = the command that is currently being processed (00H to 3EH).
AC Voltage = voltage at the charger input, 0 to 255 volts, 0 to 255 Dec, 00 to FF Hex.
DC Voltage = battery voltage, 0 to 35 volts, 0 to 255 Dec, 00 to FF Hex.
Status Byte =
Bit 0 = stored FULL data,
0 = fail, 1 = pass
Bit 1 = stored PARTIAL data,
0 = fail, 1 = pass
Bit 2 = present Tone Gen BIAS state,
0 = inactive, 1 = active
Bit 3 = present Intrusion state,
0 = door closed, 1 = door open
Bit 4 = StrobeVisor™ error,
0 = no error, 1 = error
Bit 5 = stored Rotor data,
0 = stationary, 1 = oscillating
Bit 6 = SuperVisor error
0 = no error, 1 = error
Bit 7 = not defined