33
Section 10 INSPECTION
10.0 Routine Inspection
Routine inspection procedures for the IPS pertain to the basic IPS cabinet, mainly cables and connectors.
Inspection or checkout procedures for specific modules are provided below.
Routine Inspection Procedures
PROCEDURE AND
TOPIC
PROCEDURAL ACTIVITIES
Cable Inspection
Inspect all cables and connectors (i.e., from the AC Service to the system
driver board within the IPS cabinet and all other plainly exposed cables and
connections) for visible damage that might affect safety and operation. This
visible inspection should ensure that no wires have been cut and that no
connector has shorted or has loosened from its respective cable.
Connector Inspection
Inspect all connectors for bent or broken pins and corrosion. Also, inspect
all connectors for damaged threads.
Cabinet Inspection
Inspect all plainly visible aspects of the IPS cabinet to ensure that no
damage or corrosion has occurred.
Ensure that no mounting bolts, washers or nuts are loose or missing.
tighten the cabinet mounting hardware, if necessary.