Siren Command Definitions
Command
Function
___________________________________________________________________________
00H Clear
Clears any event in progress.
01H Wail
Tone Warning.
02H Attack
Tone Warning.
03H Alert
Tone Warning.
04H Public Address
Live Public Address.
05H Air-Horn
Tone Warning.
06H Hi-Lo
Tone Warning.
07H Whoop
Tone Warning.
08H Wail-2 (noon test)
Tone Warning, short tone.
09H North
Positioning command to North.
0AH East
Positioning command to IPSt.
0BH South
Positioning command to South.
0CH West
Positioning command to West.
0DH Clockwise
Positioning command to increment 45
°
clockwise.
0EH Counter clockwise
Positioning command to increment 45
°
counter-clockwise.
0FH Silent test
Initiates the diagnostic Silent Test, producing a Status response.
10H Clear
Clears any event in progress.
11H Message 13
Initiates digital voice message 13, for an RSDVM module.
12H Message 14
Initiates digital voice message 14, for an RSDVM module.
13H Message 15
Initiates digital voice message 15, for an RSDVM module.
14H Message 16
Initiates digital voice message 16, for an RSDVM module.
15H Rotor position
Rotor/speaker position request.
16H Counter
Tone activation software counter request.
17H Clear counter
Clears the software tone activation counter to zero.
18H Arm system
Arms the Instant Status response.
19H Dis-arm system
Disables the Instant Status response.
1AH Siren on
Enables the tone generator and digital voice.
1BH Siren off
Disables the tone generator, digital voice is active.
1CH Signal/Noise Req.
Executes the Signal to Noise check in a Remote Siren.
1DH Signal/Noise Status
Signal to Noise reading request.
1EH Test Clear
Clears LEDs
1FH Status Request
Retrieves the Status byte.
20H Clear
Clears any event in progress.
21H Battery/AC
Requests battery voltage and AC voltage mIPSurements.
22H Battery/Temperature
Requests battery voltage and cabinet temp. mIPSurements.
23H Instant Status
Get real time (instant) status of Remote Siren Station.
24H Transmit Off
Disables the transmit repeat feature during Instant Status.
25H Strobe Test
StrobeVisor™ only. 4 to 5 flash test period.
26H not used
27H Wind Shift
Greatest directional shift, on a sliding 10 minute window.
28H Reset Wind & Temp.
Resets the wind and temperature values.
29H Reset Rainfall
Resets the rainfall value.
2AH Weather
Requests outside temperature, wind direction, wind speed, and rainfall.
2BH Temperature
Requests cabinet temperature, outside temperature, low peak, and high peak
(peak values since last reset).
2CH Wind
Requests wind direction, speed, and peak (peak value since last reset).
2DH Rainfall
Requests totalized rainfall since last reset.
2EH Humidity
Requests the humidity reading.
2FH Barometer
Requests the barometric pressure.