23
Section 6 BATTERIES
6.0 Battery Installation
As previously mentioned, an IPS-400 comes with two 31 Amp-hour batteries. These fit as shown in the drawing.
The IPS-800 comes with two 55 Amp-hour batteries. These are larger than the 31 Amp-hour batteries. They must
be rotated 90 degrees to be installed.
6.1 Battery Connections
Unplug the battery charger from the AC outlet. Connect the red cable to the (+) terminal of the left battery.
Connect the black cable and the gray thermistor cable to the (-) terminal of the right battery. Last connect the
interconnect cable to the (-) terminal of the left battery and then the (+) terminal of the right battery.
Note: A spark may occur when the last terminal connection is made.
Battery Compartment Connections
CAUTION: Do not allow battery terminals, cables terminals or uninsulated tools
to make contact with the aluminum cabinet.
1/4"-20 X 3/4"
HEX HEAD BOLT
PPOSITIVE
CABLE
INTERCONNECT
1/4" LOCKWASHER
1/4-20 HEX NUT
THERMISTOR ASS'Y
(RED)
NEGATIVE
(BLACK)