1.2. Internal Diagram
Pic.2 - Internal diagram
1.
Isolated bidirectional inverter
: it is the AC/DC conversion system and charges and discharges the battery, in
accordance with the management profile; it receives the set-point of the charge and discharge power from the
energy manager; the nominal power in discharge is 2.4kW; the nominal power in charge is 2.1kW;
2.
Input relay
: connects the inverter in parallel with the
On-Grid
mains,
it disconnects the grid in case of off-
specification parameters (voltage and frequency);
3.
WRD
: the integrated data acquisition system for remote monitoring and setting, if properly connected to the
Internet;
4.
Energy Manager
: determines the set-point for charging and discharging power according to the production of the
existing PV plant and the consumption of the domestic system;
1
LEONARDO PRO X
INPUT RELE'
INVERTER
BIDIREZIONALE
ISOLATO
AC
2
DC
AC-IN
AC-OUT
ENERGY
MANAGER
4
WRD
3
CAN BUS
BATTERY
ETHERNET
WBUS