4.4 Technical data and operating conditions
Model
W20 W
General data
Machine dimensions
without
front metal sheet
H x W x D (mm)
455 x 555 x 441
Machine dimensions
with
front metal sheet
H x W x D (mm)
458 x 595 x 460
Weight (kg)
47
Cooling water
Production
data
Production (kg per day)
about 20
Storage (kg)
about 5
Water consumption of ice making (litres
per kg)
about 3
Water consumption of cooling system
(litres per kg)
about 15
Power
supply
Voltage
230 V ~ / 50 Hz
Power consumption
0,30 kW
Fuse (provided by customer)
≥
10 A
Length of connection cable
about 2,0 m
Water
supply
Pressure
2 to 6 bar (28,6 to 85,7psi)
Temperature (ideal/ permitted)
10–15 °C/ 2–25 °C
Water hardness
max. 15 °dH (19 °e) *)
Water
inlet
device connection -Ø
¾ “
hose –Ø / -length
OD:10 mm – ID:7 mm / about 2,0 m
Water outlet
device connection -Ø
20 mm
hose –Ø / -length
DN 20 / about 0,215 m
Bursting pressure - water cycle
15 bar
Cooling cycle
Bursting limit
70 bar
Environmental
conditions
Temperature (ideal/ permitted)
15-20 °C/ 10-45 °C
Installation position
firm surface, good ventilation
Installation height
at least 10 cm above outlet pipe
The installation surface must be suitable for the weight of the machine.
*) If the water hardness exceeds the maximum value, the use of a softener is recommended.