Models C1448R, C1848R,
C2148R
Страница 1: ...Installation and User s Manual for Remote Condenser Modular Cuber Prodigy Plus E Series Models C1448R C1848R C2148R ...
Страница 2: ... to properly install and start up this ice system The Use and Operation section provides the user with the information needed to use the machine The Maintenance section contains the instructions and schedules for the sanitation and cleaning of the machine Contents Installation Product Specifications Page 2 Model Number Description Page 3 Product Description and Electrical Requirements Page 4 Conde...
Страница 3: ... by warranty Environmental Limitations Ice machine Minimum Maximum Air temperature 50o F 100o F Water temperature 40o F 100o F Water pressure 20 psi 80 psi Remote condenser Minimum Maximum Air temperature 20o F 120o F Power Supply Minimum Maximum 208 230 volt model 198 volts 253 volts Warranty Information The warranty statement for this product is provided separately from this manual Refer to it f...
Страница 4: ...re bin or dispenser adapters See the table below Standard bin applications Adapter information Model BH900 or B948 BH1100 BH1300 or BH1600 C1448 C1848 or C2148 Direct fit no adapter needed Adapter panels included with bin no adapter needed If stainless steel Kbaffle3 has been installed remove it and replace with the original plastic baffle Other bins and applications Note the drop zone and optiona...
Страница 5: ...to be on whenever the ice machine is operating U L listed for the ice machine Non Scotsman condensers must have prior Scotsman Engineering approval for warranty coverage to be in effect Refrigerant tubing kits The ice making head s and the remote condenser s refrigeration circuits must be connected They are designed to be connected Scotsman refrigerant tubing supplied in kits of liquid and dischar...
Страница 6: ...2 1 cm 11 50 in 29 2 cm 15 0782 01 CAN CAUSE INJURY OR DEATH DISCONNECT ALL REMOTE ELECTRIC POWER SUPPLIES BEFORE SERVICING RISK OF ELECTRIC SHOCK M WARNING Cond Fins REMOTECOOLED BACKVIEW 18 00 45 7 46 15 117 2 20 59 52 3 2 96 7 5 25 09 63 7 24 91 63 3 24 18 61 4 8 61 21 9 11 11 28 2 15 5 6 11 3 8 FPT WATER INLET REMOTE CONDENSER DISCHARGELINE 1 2COPPERBRAZEJOINT 88 DIA ELECTRICAL ACCESS 2 REMOTE...
Страница 7: ...quent sanitation cleanings due to the tendency of these materials to contaminate the machine Most water filters remove chlorine from the water supply to the machine which contributes to this situation Testing has shown that using a filter that does not remove chlorine such as the Scotsman Aqua Patrol will greatly improve this situation while the ice making process itself will remove the chlorine f...
Страница 8: ...e dataplate on the condenser near the quick connect fittings Write the model and serial number of the ice machine here Write the model and serial number of the remote condenser here Write the model and serial number of the ice storage bin here Write the day of initial start up here That day starts the warranty period Uncrate and Set Up Begin with the ice storage bin Remove the carton and using par...
Страница 9: ...ce in feet Calculation Drop s Rise s Horizontal Run dd rd hd Calculated Line Length Configurations that do NOT meet these requirements must receive prior written authorization from Scotsman Do NOT Route a line set that rises then falls then rises Route a line set that falls then rises then falls Calculation Example 1 The condenser is to be located 5 feet below the ice machine and then 20 feet away...
Страница 10: ... guard Space at the coil sides must also be at least 24 inches from a wall Note The location of the condenser relative to the ice machine is LIMITED by the specification on the prior page Meet all applicable building codes Roof Attachment Install and attach the remote condenser to the roof of the building using the methods and practices of construction that conform to the local building codes incl...
Страница 11: ...bs are round dress with swage tool if needed At Head 1 Remove the tubing access bracket to allow more room for brazing 1 Confirm connection ball valves are fully closed 2 Remove protective plugs from both connections 3 Remove caps from access valve connections 4 Remove cores from access valves 5 Connect refrigeration hoses to access valves 6 Connect dry nitrogen source to liquid line connection 7 ...
Страница 12: ...e back of the cabinet Install new tubing when replacing a prior ice machine as the tubing will have been sized for the old model and might not be correct for this one 1 Connect water supply to water inlet fittings 2 Connect drain tubing to drain fitting 3 Route the drain tubing to building drain Follow local codes for air gap 4 Use rigid drain tubes and route them separately do not Tee into the bi...
Страница 13: ... machine A separate knockout hole has been provided in the ice maker electrical junction box Electrical connections are made inside the junction box in the back panel of the ice machine 1 Remove the junction box cover and route the power cord through the access hole and properly attach the power supply wires to the leads in the junction box 2 Attach the remote condenser fan motor wires to the wire...
Страница 14: ...oved 12 Is the water pressure adequate 13 Have the drain connections been checked for leaks 14 Has the bin interior been wiped clean or sanitized 15 Have any water filter cartridges been replaced 16 Have all required kits and adapters been properly installed Lower Light and Switch Panel This user accessible panel provides important operational information and duplicates the lights and switches on ...
Страница 15: ...al position Note Moving the curtain during the Freeze cycle has no affect on unit operation 8 Observe the Ready for Harvest indicator light It may blink early in the freeze cycle that is normal The control will ignore that signal for the first 6 minutes of freeze 9 When the ice has frozen enough the Ready for Harvest indicator light will be on steady After it s been on steady for a few seconds Har...
Страница 16: ...if needed Water purge setting The water purge is factory set to the automatic position suitable for most water conditions The setting can be changed to one of 5 manual settings or left on automatic Purge setting 1 Minimum 2 Moderate 3 Standard 4 Heavy 5 Maximum A Automatic Water Type RO water or equivalent Factory Setting for typical water High TDS water Any with conductivity not less than 10 micr...
Страница 17: ...dy Green Normal Normal bin full or making ice Blinking Green Self Test Failure Switching on or off Blinking Red Diagnostic shutdown or if making ice temperature sensor failure Lack of water Yellow Time to de scale and sanitize Blinking Yellow In Cleaning mode Light off No power Switched off Normal Normal All Blinking Unit remotely locked out check with leasing company If the Water light is on the ...
Страница 18: ... Seasonal changes in ice used Planning to sanitize the bin Faster turnover for fresher ice Certain dispenser applications where maximum ice level is not desired Use of adjustable ice level control There are several positions the ice level can be set to including Off knob and label indicators lined up where it fills the bin until the standard bin control shuts the machine off See the kit s instruct...
Страница 19: ...n the reservoir and begin to refill it Note Curtains must be in the closed position Move curtains to release any ice trapped after ice is harvested 5 Observe code display when it blinks the characters A d 1 immediately go to the next step 6 Pour 24 ounces of Scotsman Clear 1 ice machine scale remover into the reservoir The unit will circulate the scale remover then drain and flush it This will tak...
Страница 20: ... water distributors and curtains to their normal positions Be sure water level sensor and ice thickness sensor are completely dry 18 Push and release the Clean button The yellow Clean light will blink and the display will show C The machine will go through a harvest cycle drain the reservoir and begin to refill it 19 Observe code display when it blinks the characters Ad1 immediately go to the next...
Страница 21: ... with compressed air from the inside or use a vacuum cleaner and soft brush Be careful not to damage the condenser s fins Use a fin comb to straighten any bent fins Exterior Panels The front and side panels are durable stainless steel Fingerprints dust and grease will require cleaning with a good quality stainless steel cleaner Water filters If the machine has been connected to water filters check...
Страница 22: ...art when power is restored 3 Has someone shut the power off to the remote condenser while the ice machine still had power If yes the ice machine may need to be manually reset 4 Is a curtain open because some ice is stuck under it If so remove the ice and the machine should start in a few minutes Note Curtains can be removed replaced anytime the machine is in a standby mode or when it is in a freez...
Страница 23: ...SCOTSMAN ICE SYSTEMS 101 Corporate Woods Parkway Vernon Hills IL 60061 800 726 8762 www scotsman ice com 17 3599 04 Rev A Last Revised 07 02 18 ...