SPECIFICHE TECNICHE
DATI TECNICI:
Funzionamento ..................................................elettro-idraulico
Portata ................................................................4000 Kg
Tempo di salita ...................................................35
sec.
Tempo di discesa................................................45
sec.
Alimentazione pneumatica..................................4
:
8
bar
Rumorosità..........................................................
<
74 db
Peso totale ..........................................................circa 660 Kg
Temperatura di funzionamento ...........................-10°C / +50°C
Ambiente di lavoro: locale chiuso.
Il senso di rotazione del motore è sinistro, cioè antiorario, come indicato
dalla targhetta sul motore stesso.
MOTORE ELETTRICO
Tipo ...........................................................G 80
Potenza .....................................................2.2 Kw
Tensione....................................................230-400 V trif. +/- 5%
Frequenza .................................................50 Hz
N° poli........................................................2
Velocità .....................................................2800 giri/1’
Forma costruttiva.......................................B14
Classe isolamento .....................................F
Assorbimento: ...........................................230V: 14.4A
..................................................................400V: 7,5A
Servizio .....................................................S3 12min
Protezione .................................................IP54
Il collegamento del motore deve essere eseguito riferendosi agli schemi
elettrici allegati. Il senso di rotazione del motore è sinistro (antiorario)
come indicato nella targhetta applicata sul motore stesso.
CENTRALINA OLEODINAMICA:
Pompa .......................................................ad ingranaggi
Cilindrata ...................................................2,6 cm
3
/g
Valvola di max. tarata a .............................330 bar
OLIO
Il serbatoio dell’olio contiene oilio idraulico a base minerale secondo
normativa ISO/DIN 6743/4 con grado di contaminazione non superiore
alla classe 18/15 secondo normativa ISO 4406 come IP HYDRO OIL
32; SHELL TELLUS T 37 o equivalenti.
CHAPTER 2
SPECIFICATIONS
TECHNICAL DATA:
Operation...................................................electro-hydraulic
Carrying Capacity......................................4000 kg
Lifting time .................................................35
sec.
Lowering time ............................................45
sec.
Pneumatic supply ......................................4-8
bar
Noisy level .................................................
<
74 db
Weight .......................................................660 kg. approx.
Working temperature.................................-10°C / +50°C
Installation requirements: enclosed area.
The motor rotates towards left, i.e. its rotation is counterclockwise , as
shown in the label placed on the motor.
MOTOR
Type ..........................................................G 80
Power ........................................................2.2 Kw
Voltage ......................................................230-400V th.-ph +/-5%
Frequency .................................................50 Hz
Poles .........................................................2
Speed ........................................................2800 rpm
Building shape...........................................B14
Isulation class............................................F
Absorption: ................................................230V: 14.4A
..................................................................400V: 7,5 A
Service ...................................................... S3 12 Min
Insulation class.......................................... IP54
When connecting the motor refer to the enclosed wiring diagrams.
The motor has left-handed rotation (counter-clockwise) as shown on the
data plate on the casing.
HYDRAULIC CONTROL UNIT:
Type ..........................................................Gear pump
Displacement ............................................2,6 cm
3
/g
Relief valve:...............................................330 bar
OIL
The hydraulic oil tank is filled with mineral oil according to ISO/DIN
6743/4, contamination category no higher than class 18/15 according to
ISO 4406, such as IP HYDRO OIL 32; SHELL TELLUS T 37 or an equi-
valent oil.
12
ESTENSIONE INTEGRATA EXTENSION
RALLONGE INTÉGRÉE - Aufnahmeplatten Auszug
EXTENSION INTEGRADA
Содержание STRATOS S39
Страница 2: ......
Страница 28: ...26 ...
Страница 50: ......
Страница 52: ...QUADRO DI COMANDO CONTROL BOX STEUERTAFEL TABLEAU DE COMMANDE PANEL DE MANDO ...
Страница 53: ...CENTRALINA OLEODINAMICA OLEODYNAMIC CONTROL UNIT HYDRAULIKEINHEIT CENTRALE HYDRAULIQUE CENTRALITA HIDRAULICA ...