15
Designation
Function
Impulse
Adjusting impulse duration
Impulse
+
−
Impulse
0 ms
Impulse duration defines how long the
output signal remains in the activated
state. Impulse duration can be set to a
value within a range of 0 to 10.000 ms
by pressing the + or the – key.
If the value is set to “0 ms” the function
is deactivated.
After the selected impulse duration has
elapsed, the output signal is returned
to the deactivated state..
Function can be combined with
ON Delay.
Extern T
External Teach-In
A1 Switch
T Object
T Backgrnd.
Window
By pressing the button
can be selected, if an “Object Teach-In”, a “Background
Teach-In”, or “Teach-In of a tolerance window” is executed at the External Teach-In.
7.4. A3 Error/A3 Input
7.4.1. A3 Error
The error output is activated if no light signal is returned to the Sensor.
Designation
Function
NPN/PNP
Configuring the error outputs
P
N
PnP
npn
The error output is preset to PNP. Pressing the
N key sets the error output to push-
pull. Pressing the
N key again sets the error output to NPN.
The respective circuit diagram indicates how the output is set:
PNP Push-pull NPN
pnp
PnP
npn
npn
NO/NC
Configuring the error outputs
NO/NC
NO
NC
no
Error Outputs can be set up as normally open or normally closed by pressing the
NO
or the
NC key. The respective circuit diagram is displayed.