20
EN
Example of application:
A OPT2013 is used in a high rack warehouse with varying ambient temperatures. To eliminate the temperature
drift, a reference path of 1000 mm is specified to the Sensor as the specification offset. Through an external trig-
ger Sensor, the specification offset is applied and given to the Sensor as the current distance. This ensures that
the distance tallies with the value of the reference route with every trigger signal and thus, the varying ambient
temperature has no influence on the measurement values of the Sensor.
Movement path of sensor
Reference path
1000 mm
Trigger sensor:
Switch output, sensor on
PIN A3/V of the LLZ-sensor
High rack stores
7.7. Measure Rate
Reducing the measure rate improves resolution and reduces minimum selectable switching hysteresis.
The respective minimum and maximum values are in the table on page 6.
Designation
Function
MeasureRate
100 Hz
50 Hz
20 Hz
10 Hz
5 Hz
2 Hz
1 Hz
Measure rate value
The measure rate which is best suited for the respective application can be selected from the predefined
values by pressing the
or the
key.
7.8. Laser
Transmitted light can be either deactivated or activated with the help of the
Laser menu.
Designation
Function
Laser
ON
OFF
ON: Switch transmitted light on
OFF: Switch transmitted light off
Transmitted light is deactivated or activated by pressing the
or the
key.
In case of the OPT2013 the laser diode can be switched off via pin 8, by connecting pin 8 to 24 V.
Содержание OPT2012