6
EN
Measuring Range:
The Sensors’ measuring range is determined by object remission.
Maximum range of
OPT2013, OPT2014 OPT2012
Up to 10 m on white (90 % remission)
Up to 6 m on white (90 % remission)
Up to 5 m on gray (18 % remission)
Up to 5 m on gray (18 % remission)
Up to 3 m on black (6 % remission)
Up to 3 m on black (6 % remission)
Light Spot Diameter
Working Distance
0
6 m
10 m
Light Spot Diameter
5 mm
< 12 mm
< 20 mm
Dependence of Hysteresis and Resolution on the Sampling Rate on white (90 % Remission)
OPT2013, OPT2014
Selected sampling
rate in Hz
Default setting for min.
hysteresis in mm
Resolution in mm
0,1…3 m
3…5 m
5…10,1 m
100
20
3
5
12
50
15
2
3
10
20
10
2
2
8
10
8
1
2
7
5
6
1
2
6
2
4
1
1
6
1
3
1
1
6
OPT2012
Selected sampling
rate in Hz
Default setting for min.
hysteresis in mm
Resolution in mm
0,2…3 m
3…5 m
5…6 m
100
20
3
5
12
50
15
2
3
10
20
10
2
2
8
10
8
1
2
7
5
6
1
2
6
2
4
1
1
6
1
3
1
1
6
Содержание OPT2012