Without Offset equalization:
In the diagram, the Sensor measures a distance of 5000 mm.
The switching point is located 2000 mm distant, at 7000 mm.
5000 mm
7000 mm
Switching Point
[Distance measured with
a meter ruler(mm)]
With application of the offset equalization: Specification offset: 0 mm
In the diagram, the Sensor measures a distance of 5000 mm. The switching point is located 2000 mm distant,
at 7000 mm. After application of the offset equalization, from the distance 5000 mm the distance becomes
0 mm. The switching distance thus gets displaced by 7000 mm to the actual 12000 mm.
5000 mm
12000 mm
Switching Point
[Distance measured with
a meter ruler (mm)]
0 mm
Switching Distance: 7000 mm
Application of the offset equalization
Application of the offset equalization: Specification offset: 3000 mm
In the diagram, the Sensor measures a distance of 5000 mm. The switching point is located 2000 mm distant,
at 7000 mm. After application of the offset equalization, from the distance 5000 mm the distance becomes
3000 mm. The switching distance thus gets displaced by 4000 mm to the actual 9000 mm.
5000 mm
9000 mm
[Distance measured with
a meter ruler (mm)]
3000 mm
Switching distance set: 7000 mm
Application of the offset equalization
3000 mm
4000 mm