Installation (continued)
Ceiling Panels (continued)
3. Locate the next inside ceiling panel in the order according to the layout plan drawing.
IMPORTANT: Male roto locks must be used in all end ceiling panels.
Switching roto lock configuration between male and female may be required
on mating panels.
4. Place the ceiling panel next to the end ceiling panel on top of the frame rail. Position the panel
edges to be flush with the edges of the previously installed panel
5. Loosely attach the ceiling panel to the frame rail using a
1
/
4
" flat washer and a
1
/
4
-20 x
3
/
4
" capscrew through both of the pre-drilled holes in the frame rail and into the
cage nut of the ceiling panel.
Turn both male roto locks located on the under-side of the end ceiling panel to secure both
ceiling panels together.
6. Continue to install the remaining ceiling panels using these steps according to the layout plan
drawing. Roto locks for the inside ceiling panels are turned from the bottom-side of the ceiling
panels.
7. Tighten all of the capscrews used to attach the ceiling panels to the frame rail on the
inside of the room.