![Wenger SoundLok Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/wenger/soundlok/soundlok_assembly-instructions-manual_956773011.webp)
11
Installation (continued)
Wall Panel Installation
If the optional Inset Floor has been installed, the Inset Floor Door Trim should now be installed
following the procedure in 271A210.
1. Locate and identify all of the wall panels sections. These must be installed exactly as indicated
in the layout plan drawing.
2. Start the wall panel installation on the right-hand side of the door assembly when standing
inside of the room.
3. Locate the wall panel section for this location according to the layout plan drawing
(in this case it is a corner panel).
Place the first wall panel section into position, next to the door assembly and into the
channel on the top of the floor frame. The surface with rubber seals is the bottom and
contacts the floor frame.
4. Attach the wall panel section to the door assembly by turning the roto locks located at the
left-hand inside edge of the wall panel section.
The roto locks are contained behind the inside skin panel.
Note:
The upper and lower roto locks turn in opposite directions.
This allows the wall panel to move up and down
for perfect alignment and seal.
Locked panels must be flush along the top
and sealed with the floor frame at the bottom.
a. Using a
5
/
16
" hex allen wrench, turn the
lower
roto lock clockwise until the top of the wall panel
is flush with the top of the door assembly.
b. Using a
5
/
16
" hex allen wrench, turn the
upper
roto lock counter-clockwise until it is tight.
c. Finish tightening the upper roto lock by
turning it clockwise. Make sure the wall panel
is flush with the door assembly at the top.
Repeat these steps until they are flush.
First Wall Panel
Section, Rubber Seal
Surface Contacts
Floor Frame
Upper Roto Lock
Turns
Counter-Clockwise
Lower Roto Lock
Turns
Clockwise
The roto locks are located behind the inside skin panel.
The inside skin panel is shown hidden for clarity.