Part Number STH047 Rev01 10/18 65
Safety Limit Notes
• A safety limit indication is completed before the water
pump starts. Water contacting the ice thickness probe
in the freeze cycle will cause the harvest light to flash.
Do not mistake a harvest light flashing in the freeze
cycle with a safety limit indication.
• A continuous run of 100 harvests automatically erases
the safety limit code.
• The control board will store and indicate only one
safety limit – the last one exceeded.
• If the toggle switch is moved to the OFF position and
then back to the ON position prior to reaching the
100-harvest point, the last safety limit exceeded will
be indicated.
• If the harvest light did not flash prior to the ice
machine restarting, then the ice machine did not stop
because it exceeded a safety limit.