108
Part Number STH047 Rev01 10/18
4. Recovered refrigerant must come from a
“contaminant-free” system. To decide whether the
system is contaminant free, consider:
• Type(s) of previous failure(s)
• Whether the system was cleaned, evacuated and
recharged properly following failure(s)
• Whether the system has been contaminated by
this failure
• Compressor motor burnouts and improper past
service prevent refrigerant re-use.
• Refer to “System Contamination Cleanup” on page
112 to test for contamination.
5. “Substitute” or “Alternative” Refrigerant
• Must use only Koolaire®-approved alternative
refrigerants.
• Must follow Koolaire®-published conversion
procedures.
Содержание Koolaire KD0270A
Страница 2: ......
Страница 16: ...16 Part Number STH047 Rev01 10 18 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 44: ...44 Part Number STH047 Rev01 10 18 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 52: ...52 Part Number STH047 Rev01 10 18 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 92: ...92 Part Number STH047 Rev01 10 18 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 118: ...118 Part Number STH047 Rev01 10 18 FIG A PINCHING OFF TUBING FIG B RE ROUNDING TUBING SV1406 Using Pinch Off Tool...
Страница 120: ...120 Part Number STH047 Rev01 10 18 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 135: ......