Dimen‐
sion
Meaning
Required space
B
Minimum required space for the unit width when the door is
opened 90°
[in]
24.9
B'
Minimum required space for the unit width when the door is
opened 180°
[in]
41.5
D
Minimum required space for the unit depth (including open
door)
[in]
51.8
a
Minimum wall clearance on the left side of the unit
[in]
2.0
b
Minimum wall clearance at the back of the unit
[in]
2.0
c
Minimum wall clearance on the right side of the unit
[in]
2.0
Minimum space requirements – height
The following diagram and table show the vertical space required by the unit:
H1
H2
The service technician responsible for setting up the unit must take into account the ceiling's proper‐
ties and any adjacent systems being used (air ventilation system, range hood) when determining the
actual clearance required between the top of the unit and the ceiling. Vertical clearance H1 is only
meant to serve as a reference point for the minimum vertical clearance.
Dimen‐
sion
Meaning
Required space
H1
Reference point for minimum vertical clearance
[in]
20.0
H2
Installation height
[in]
27.6 - 35.4
The topmost shelf must not be at a height exceeding 63".
This requirement will be met automatically if the unit is set up on one of the manufacturer's equipment
stands. Please refer to Equipment stand dimensions and weights for more information.
5 Setup
Installation Manual
43
Содержание Convotherm mini black easyTouch 10.10
Страница 1: ...Combi Oven OES 6 10 mini easyTouch Installation manual UL USA Original ENG ...
Страница 2: ......
Страница 4: ......
Страница 74: ......
Страница 76: ...Combi Oven OES 10 10 mini easyTouch Installation manual UL USA Original ENG ...
Страница 77: ......
Страница 79: ......
Страница 147: ......