Y
Shut-off device with mesh
strainer
Water valve
V
Appropriate backflow prevent‐
er
The unit must be installed with an appropriate backflow pre‐
venter in order to comply with all applicable federal, state,
and local laws and regulations.
Installing the water supply connection
Follow the steps below to set up the water supply for your combi oven:
Step
Procedure
1
Ask your local water company for information regarding the quality and hardness of the wa‐
ter you get. If required, use suitable water treatment solutions.
For information on the required properties for the fresh water used with the unit, please re‐
fer to the Technical Data on page 70 section.
2
Flush the water connection on the on-site water line (Z).
3
Install the sediment filter (X) and, if necessary, a water treatment system (W).
4
Install a separate shut-off device with a mesh strainer for each unit (Y or Y
1
/Y
2
).
5
Install an appropriate backflow preventer (V) in the water supply line if required by local
regulations.
6
Connect the unit as shown in the connection drawing.
7
Flush the sediment filter and, if applicable, the water treatment system.
8
Once you are done installing the water connection, close the shut-off device.
9
Inform the user of the maintenance intervals for the filters and for the water treatment sys‐
tem (if any).
6 Installation
Installation Manual
56
Содержание Convotherm mini black easyTouch 10.10
Страница 1: ...Combi Oven OES 6 10 mini easyTouch Installation manual UL USA Original ENG ...
Страница 2: ......
Страница 4: ......
Страница 74: ......
Страница 76: ...Combi Oven OES 10 10 mini easyTouch Installation manual UL USA Original ENG ...
Страница 77: ......
Страница 79: ......
Страница 147: ......