- 59 -
Index
Funktion
Zugriff
Subindex
Datentyp
Beschreibung
Werkseinstellung
0x86
Virtualiza-
tion 7
Read /write
1
UIntegerT(8)
Animation
2
UIntegerT(8)
Color
3
UIntegerT(8)
Speed
0x90
Virtual posi-
tion switch 0 Read /write
1
IntegerT(16)
Switch position in
1/100 mm
0
2
UIntegerT(16)
Switch position in
1/100 mm
200
0x91
Virtual posi-
tion switch 1 Read /write
1
IntegerT(16)
Switch position in
1/100 mm
0
2
UIntegerT(16)
Switch position in
1/100 mm
200
0x92
Virtual posi-
tion switch 2 Read /write
1
IntegerT(16)
Switch position in
1/100 mm
0
2
UIntegerT(16)
Switch position in
1/100 mm
200
0x93
Virtual posi-
tion switch 3 Read /write
1
IntegerT(16)
Switch position in
1/100 mm
0
2
UIntegerT(16)
Switch position in
1/100 mm
200
0xA0
Diagnosis
Read Only
1
UIntegerT(16)
Duration of the last
successful gripping
operation in millisec-
onds
-
2
UIntegerT(16)
Duration of the last
successful gripping
operation in millisec-
onds
-
3
IntegerT(16)
Current module tem-
perature in 1/10 °C
-
4
UIntegerT(32)
Gripping cycle count
-
5
IntegerT(32)
Cycles remaining un-
til next maintenance
-
0x100
Protocol
Entry 0
Read Only
1
UIntegerT(32)
Time stamp meas-
ured in seconds since
activation
0
2
StringT(140)
Message text (max.
140 characters)
"(not set)"
…
0x109
Protocol
Entry 9
Read Only
1
UIntegerT(32)
Time stamp meas-
ured in seconds since
activation
0
2
StringT(140)
Message text (max.
140 characters)
"(not set)"
Содержание 5120012
Страница 1: ...Mounting and Operating Manual CRG Series Electrical Gripping Modules with IO Link October 2020...
Страница 63: ...62 Figure 22 Configuration of the IO Link master Figure 23 Starting the S7 PCT port configurator device tool...