Part number 550-100-305/0118
97
AquaBalance
TM
W
ALL
M
OUNT
GAS
-
FIRED
WATER
BOILER
—
Boiler Manual
34
Troubleshooting
(continued)
t01
blinking
CH Supply sensor1 Temperature (°F)
between 32 and 257
t02
blinking
CH Supply sensor2 Temperature (°F)
between 32 and 257
t03
blinking
CH Return sensor Temperature (°F)
between 32 and 257
t04
blinking
DHW sensor Temperature (°F)
between 32 and 257
t05
blinking
Outdoor sensor Temperature (°F)
between -22 and 158, blinking if it is negative
t06
blinking
Exhaust sensor Temperature (°F)
between 32 and 257
F07
blinking
Actual Blower Speed (Hz)
\]"""ZX^XXX]\]!
L08
blinking
Actual burner load (%)
\]|" #^`^`^
F09
blinking
^`"Q;"^X$;"^XQZ\]
between 00 and 255
“In” as Inquiry mode
Selecting “In” the display starts with showing “
t01
” blinking. By means of the CH+ and CH- push buttons it is possible to select the
parameters; between “
t01
” and “
F13
”. Selecting one of these parameters, by means of the DHW+ and DHW- push buttons is pos-
sible to see his value (not flashing; only in case of negative outdoor temperature the value is flashing).
Boiler
Model
“b01”
“b02”
“b04” “b05” “b06”
“b10” “b12”
“P01”
“P02”
“P04”
Gas
type
Boiler
type
Fan Max.
Freq. in DHW
Fan Max.
Freq. in CH
Fan Min.
Freq. in CH
S/W mode
selection button
Var. Out
Relay
Ignition
level
CH Slope
(F/min)
CH
Off Time
WMB-80-N-C
?"^!"#
3
155
155
40
1
0
80
6
2
WMB-120-N-C
?"^!"#
3
200
200
40
1
0
60
6
2
WMB-155-N-C
?"^!"#
3
205
205
39
1
7
60
6
2
WMB-80-N-H
?"^!"#
2
155
155
40
1
0
80
6
2
WMB-120-N-H
?"^!"#
2
200
200
40
1
0
60
6
2
WMB-155-N-H
?"^!"#
2
205
205
39
1
0
60
6
2
WMB-80-LP-C
~
3
145
145
40
1
0
80
6
2
WMB-120-LP-C
~
3
185
185
40
1
0
60
6
2
WMB-155-LP-C
~
3
210
210
40
1
7
60
6
2
WMB-80-LP-H
~
2
145
145
40
1
0
80
6
2
WMB-120-LP-H
~
2
185
185
40
1
0
60
6
2
WMB-155-LP-H
~
2
210
210
40
1
0
60
6
2
Parameter Description
Default
Note
P33
?^\ZQXZX]^XJ]{!
~\\^X\XX^Z\]J]{!|
?^\ZQXZX]^XJ]{!
~\\^X\XX^Z\]J]{!
--
30
--
30
DHW conf. dependent
P34
?^\ZQXZX]^XJ]{!
~\\^X\XX#X^Z\]J]{!|
?^\ZQXZX]^XJ]{!
~\\^X\XX#X^Z\]J]{!
--
15
--
15
DHW conf. dependent
Figure 122
“tS” - Transparent Parameter mode (continued)
Figure 123
Default Control Board “Transparent Parameters”
Figure 124
“In” - Inquiry mode
By pressing the “
reset
” push button for 1 second, it is possible to escape from the “Transparent parameter” mode. By pressing the
“
reset
” push button for 20 seconds, it is possible to leave the Installer mode. If no action has been taken, the MMI automatically
leaves this mode after 15 minutes.