UNITY 500
Page 39
Page 39 of 56
800001-01
APPENDIX A
TERMINAL/MODEM MODE
A.1
TERMINAL/MODEM COMMANDS
Commands listed in this section detail command syntax and action taken. Commands consist of
a command field and a parameter field. Each command field and parameter field is separated
from others by a space. Optional parameters are indicated by square brackets, [ ], and
conditional parameters are indicated by braces, {}.
For example, COMMAND_NAME
parameter1 {parameter2} [parameter3]
indicates that
parameter1
must be entered,
parameter2
entered only when a certain condition is met (certain
option is installed, etc.), and
parameter3
is optional. Both commands and parameters may be
entered in upper or lower case; the interface is not case-sensitive.
Incorrect or incomplete commands result in "Invalid Command" being displayed at the terminal.
Parameter errors on User commands generate "Invalid
parameter name
" where
parameter name
is the name of the incorrectly entered parameter.
A.1.1
Network-enabled Local Control Commands
These commands are allowed
only if local control is enabled
and are given in Section
A.1.1
(Page 39). Commands that are always functional are given in Section
A.1.2
(Page 41).
ABORT
Insert is terminated. See TEMP command.
ADDS
location settings
location:
Value from 1 - 48 indicating location in settings_table.
settings: See
Perms/Temps/Searching & Settings Section
3.1
.
The
settings
are added to the settings_table at the specified location. Will also handle data
rate rounding as explained for PERM.
AUXDATA
[PID] [baud] [parity]
PID:
Selects the PID
(in hex)
for the Transport packets carrying the desired data stream.
Must be ‘20’ to ‘1ffe’ inclusive.
baud:
Selects the baud rate of the async data stream. Normally 19200.
parity
: Sets the parity for the data output. Normally “None.”
Sets up the Aux Data serial port device.
DELS
location
location:
Value from 1 - 48 indicating location in settings_table.
The entry in the settings table at the specified location is deleted. Ignored if only one
entry in settings table.
Содержание UNITY500
Страница 2: ...Page 2 UNITY500 800001 01 Page 2 of 56 This Page Intentionally Left Blank ...
Страница 4: ...Page 4 UNITY500 800001 01 Page 4 of 56 This Page Intentionally Left Blank ...
Страница 6: ...Page 6 UNITY500 800001 01 Page 6 of 56 This Page Intentionally Left Blank ...
Страница 10: ...Page 10 UNITY500 800001 01 Page 10 of 56 This Page Intentionally Left Blank ...
Страница 20: ...Page 20 UNITY500 800001 01 Page 20 of 56 This Page Intentionally Left Blank ...
Страница 52: ...Page 52 UNITY500 800001 01 Page 52 of 56 This Page Intentionally Left Blank ...
Страница 54: ...Page 54 UNITY500 800001 01 Page 54 of 56 This Page Intentionally Left Blank ...