WELD THE WORLD
C
od
. 006.0001.0940
16/04/2018 V.2.25
WF-104
WF-108
30
ENGLISH
7 ALARM MANAGEMENT
This LED illuminates if an incorrect operating condition occurs.
An alarm message will appear on display
D4.
Tab. 4 - Alarm messages
MESSAGE
MEANING
EVENT
CHECKS
WARNING
POWER
SOURCE
Indicates tripping of the welding
power source thermal protection.
Leave the unit running so that the
overheated components cool as
rapidly as possible.
When the problem is solved, the
welding power source will reset
automatically.
All functions disabled.
Exceptions:
•
cooling fan.
•
cooler (if switched on).
•
Make sure that the power re
-
quired by the welding process is
lower than the maximum rated
power output.
• Check that the operating condi-
tions are in compliance with the
welding power source data plate
specifications.
•
Check for the presence of ad
-
equate air circulation around the
welding power source.
WARNING
NO COMMU-
NICATION
Indicates the presence of prob
-
lems in data communication be-
tween the power source and wire
feeder.
When the problem is solved, the
welding power source will reset
automatically.
Exit the alarm state by performing
one of the following actions:
•
Switch the power source off.
All functions disabled.
Exceptions:
•
cooling fan.
•
cooler (if switched on).
• Check that the connecting cable
between power source and wire
feeder is intact and make sure
the connectors are securely
tightened.
• Check the data transmission
wiring inside the power source
and the wire feeder.
•
Check for correct operation of
the control board in the power
source and the Motor Board in
the wire feeder.
WARNING
TRIGGER
Indicates that when the wire feed
-
er was powered up a short circuit
was detected on the torch trigger
input.
When the problem is solved, the
welding power source will reset
automatically.
All functions disabled.
• Make sure the torch trigger is
not pressed, jammed, or short
circuiting.
• Make sure the torch and MIG/
MAG torch connector are intact.
WARNING
COOLING
SYSTEM
Indicates insufficient pressure in
the torch liquid cooling circuit.
To exit the alarm condition and
perform an operating check of the
cooling unit press the following
button:
All functions disabled.
Exceptions:
•
cooling fan.
• Check that the connection to the
cooler is correct.
•
Check that the O/I switch is set
to I and that it illuminates when
the pump is running.
•
Check that the cooler is filled
with coolant.
• Check that the cooling circuit is
intact, notably the torch hoses
and the internal connections of
the cooler.
WARNING
PROTEC-
TION CUR-
RENT
Indicates tripping of the welding
power source current surge pro
-
tection.
Exit the alarm state by performing
one of the following actions:
•
Switch the power source off.
•
Press the following button:
All functions disabled.
Exceptions:
•
cooling fan.
•
cooler (if switched on).
• Check that the programmed arc
voltage value is not too high in
relation to the thickness of the
work to be welded.
Содержание WF-104
Страница 1: ...Cod 006 0001 0940 16 04 2018 V 2 25 WF 104 WF 108 Instruction Manual ENG...
Страница 10: ...WELD THE WORLD Cod 006 0001 0940 16 04 2018 V 2 25 WF 104 WF 108 10 ENGLISH WF 108 RC...
Страница 69: ...WELD THE WORLD Cod 006 0001 0940 16 04 2018 V 2 25 WF 104 WF 108 69 ENGLISH...
Страница 86: ...WELD THE WORLD Cod 006 0001 0940 16 04 2018 V 2 25 WF 104 WF 108 86 ENGLISH KIT WF 108 1 2 1 3 4 5 6 7...
Страница 88: ...WELD THE WORLD Cod 006 0001 0940 16 04 2018 V 2 25 WF 104 WF 108 88 ENGLISH 15 3 WIRE FEEDER MOTOR...
Страница 94: ...WELD THE WORLD Cod 006 0001 0940 16 04 2018 V 2 25 WF 104 WF 108 94 ENGLISH...
Страница 95: ...WELD THE WORLD Cod 006 0001 0940 16 04 2018 V 2 25 WF 104 WF 108 95 ENGLISH...