6.4 TORCH LOADING
WARNING!
Make sure the torch in use is correctly sized in relation to the welding current required and for the
available and selected cooling type. This prevents the risk of burns to which the operator is potentially
exposed, potential faults, and irreversible damage to the torch and the system.
If a torch is installed or replaced while the unit is running, the circuit of the newly installed must be filled
with coolant to avoid the risk of damage to the torch in the case of high voltage arc strikes without any
liquid in the circuit.
Power-up with operation of the cooler set to "ON" or "AUTO" mode
A check is performed automatically of the presence of liquid in the cooling circuit and the cooler is
switched on for 30 seconds.
If the coolant circuit is full, the power source sets up in the most recent stable welding configuration.
If the coolant circuit is not full, all functions are inhibited and there will be no output power present.
CHECK COOLING UNIT -
The message will appear in display:
D4
○
Press button
S4
or torch trigger to repeat the checking procedure for an additional 30 sec
-
onds.
•
If the problem persists rectify the cause of the alarm.
• During this checking operation, the setup menu can be accessed by pressing button
S7
for 5 seconds.
Power-up with operation of the cooler set to "OFF"
Operation of the cooler and the cooler alarm are disabled.
Welding is performed without liquid cooling of the torch.
Torch change-over with operation of the cooler set to "AUTO"
Press and release the torch trigger.
This serves to start the cooler for 80 seconds to fill the torch cooling circuit.
6.5 WELDING CIRCUIT CALIBRATION
When the wire feeder is used with the associated cable bundle, the welding circuit “r” resistance must
be measured by using the calibration function. This allows to achieve a consistent welding quality when
the cable bundle length and the torch is changed. The welding circuit resistance depends on the cable
bundle and the torch used, therefore the calibration procedure must be repeated when these compo
-
nents are changed.
CALIBRATION after power source RESET
If the power source total RESET is carried out, the calibration value will be replaced by the default value.
If a partial RESET is carried out, the measured value will be stored.
Calibration is not compulsory therefore, should the user decide not to carry it out, the machine will keep
the default value.
Содержание WF-104
Страница 1: ...Cod 006 0001 0940 16 04 2018 V 2 25 WF 104 WF 108 Instruction Manual ENG...
Страница 10: ...WELD THE WORLD Cod 006 0001 0940 16 04 2018 V 2 25 WF 104 WF 108 10 ENGLISH WF 108 RC...
Страница 69: ...WELD THE WORLD Cod 006 0001 0940 16 04 2018 V 2 25 WF 104 WF 108 69 ENGLISH...
Страница 86: ...WELD THE WORLD Cod 006 0001 0940 16 04 2018 V 2 25 WF 104 WF 108 86 ENGLISH KIT WF 108 1 2 1 3 4 5 6 7...
Страница 88: ...WELD THE WORLD Cod 006 0001 0940 16 04 2018 V 2 25 WF 104 WF 108 88 ENGLISH 15 3 WIRE FEEDER MOTOR...
Страница 94: ...WELD THE WORLD Cod 006 0001 0940 16 04 2018 V 2 25 WF 104 WF 108 94 ENGLISH...
Страница 95: ...WELD THE WORLD Cod 006 0001 0940 16 04 2018 V 2 25 WF 104 WF 108 95 ENGLISH...