PROGRAMMING
Webasto BlueCool Classic Series
26
Note a): Ensure re-start!
Check if blower starts running at lowest speed setting to avoid motor damage.
5.4
Blower Speed Setting Calibration
Enter programming mode with setpoint at 15 °C (59 °F); proceed to following line, i.e. line <6> =
speed 5 (max). The blower will start to function as soon as you access code <6>. Alter value to the
right of code <6> and blower speed will immediately change in real time. When satisfied go to
following line <7> = speed 4 and do the same. Proceed until lowest speed No. 1 and go back again to
speed No. 5 if not satisfied. When all speeds are programmed according to need, validate by pushing
key (<MEMO> will be displayed briefly).
Code <b>
64
Access code for programming mode.
Note:
If the system is locked and the access
code cannot be found, you can access the
programming line by using the factory code
number: 64
00 = No access code
required.
01 to 99 = access
code/number
activated.
Code <c>
01
Duration in minutes of heat cycle operation
under the dehumidifying cycle.
01 - 99 min.
Code <d>
01
Duration in minutes of cool cycle operation
under the dehumidifying cycle.
01 - 99 min.
Table 4
Description of Programming Codes - setpoint at
15 °C (59 °F)
Code #
Factory
Setting
Description
Optional Settings