PROGRAMMING
Webasto BlueCool Classic Series
22
Entering programming menu level 2
• When security CODE is activated, push
when unit is in operation till CODE appears in the display.
• Set security CODE by pushing
or
and confirm with
(Default = 64).
• In case security CODE is not activated you will have direct access.
• Scroll through settings by pushing
, values can be set by
or
keys and confirmed by
for next line.
• To leave this menu push
, MEMO will be shown shortly and new settings will be memorised.
Entering programming menu level 3
• Set setpoint temperature on 15 °C or 29 °C and switch off the controller.
• Push
and
simultaneously till display lights up.
• Set security CODE when activated by pushing
or
and confirm with
(Default = 64).
• Scroll through settings by pushing
, values can be set by
or
keys and confirmed by
for next line.
• To leave this menu push
, MEMO will be shown shortly and new settings will be memorised.
5.2
Accessing Hidden Programming
To gain access to the hidden programming functions proceed as following:
1. Raise setpoint to value, i.e. 29 °C (84 °F) (or alternatively to lowest value i.e. 15 °C (59 °F))
- push
key to extinguish digital display.
2. Press
and
keys simultaneously for approx. 3 seconds until the word “CODE” is visible on
the display (1).
3. Press and hold the
key until 64 appears on the display (1) and then press the
key. Now
you are in the deep programming mode.
4. You see to the left of the display window a single number code indicating the programming line
presently valid and to the right the programming value.
5. To go to the next programming line, push the
key.
ATTENTION
If you modify the programming value of any line, you need to validate this new value by pushing the
key
again to move to the next line. This step will validate and memorize the changes made.
BLOWER SPEED
Shows actual blower speed setting, bA automatic control or b1-b5
manual, adjustable by
or
.
DOWN
Push 1x will show actual setpoint, again to lower setpoint.
UP
Push 1x will show actual setpoint, again to raise setpoint.
During operation failure codes might appear on the display (see troubleshooting), when
these are solved, controller will restart within 60 seconds.
When the same failure occurs 6 times within 30 minutes the unit will stop completely
without restart, LEDs will flash in the display until cause is solved. The counter is reset after
5 minutes of compressor operation.
Failure code A01 has a time delay of approximately 40 seconds to avoid cut-out during start-
up.