Webasto BlueCool Classic Series
THE RIGHT COOLING CAPACITY
37
10
THE RIGHT COOLING CAPACITY
*(length x width x height)
For extreme climatic conditions such as the Persian Gulf with sea-water temperatures of 32 °C and air
temperatures of 40 °C, you have to add 25 to 30 % onto the calculated figure. It is also recommended
that the condenser is increased in size.
Category 1
Volume
of the rooms
[m
3
]*
region:
portlights only
cabin(s) all below deck
[400 BTU/m
3
]
normal
cold
hot
Category 2
Volume
of the rooms
[m
3
]*
region:
average glass area
cabins partly below deck
[500 BTU/m
3
]
normal
cold
hot
Category 3
Volume
of the rooms
[m
3
]*
region:
glass area above average
saloon above deck
[600 BTU/m
3
]
normal
cold
hot
Category 4
Volume
of the rooms
[m
3
]*
region:
very large glass areas
saloon and wheel house above deck
[750 BTU/m
3
]
normal
cold
hot