Webasto BlueCool Classic Series
OVERVIEW
13
Table 1
Secondary Commands
Command
Display Readout
Setting(s)
Blower speed control
< b A> (0,1,2,3,4,5)
A = automatic blower speed adjusted to
temperature differential.
1 to 5 = manual speed control
Note: Speed control is in real time mode
i.e.changes are effective immediately
without any validation procedure.
ATTENTION
The following functions need validation before a new value is accepted. Press the
key and go to the next
function line. Validation will occur automatically when the display goes back to room temperature readout.
Validation can be forced by pushing the
key while in F mode. and is confirmed by the message <MEMO>
.
Evaporator coil temperature
<E10.2> (10.2 °C)
<E38.4> (38.4 °F)
Example (depends on setting °C or °F)
ATTENTION
The following functions do not appear in case the Digital Display Panel has been code locked.
To access these functions, see
5.1: "Programming Access"
Cycle mode choice
<F 3> (1 to 4)
The following cycle modes can be
chosen manually:
1 = cool cycle only
2 = heat cycle only
3 = automatic cycle switching with
reversible compressor
4 = automatic cycle switching without
reversible compressor
AC Voltage readout
< U232> (232 Volts)
Example
Manual on/off Compressor 1
<1C01>
<1C01> = Compressor 1 on
<1C00> = Compressor 1 off
Startup Priority Compressors
1 to 4
(only for slave Classic units)
<P123>
<P123> = 1, 2, 3, 4;
<P341> = 3, 4, 1, 2
<P A> = automatic priority rotation;
when in this priority mode, the starting
order will be changed every restart after
a thermostatic cut-out.
Time delay between
compressor startup
(only for slave Classic units)
<L 9> (9 seconds)
programmable from 1 to 9 seconds
Automatic dehumidification
while absent
<d 0>
0 = non active - factory default
1 = 1 cycle per 24H
2 = 2 cycles per 24H
3 = 3 cycles per 24H
Display time of secondary
functions (
key) by
periods of 20 seconds
<t 1>
factory default setting = 1
(for 20 seconds)