Drain Saddle fits standard 1 ¼” – 1 ½” drain pipes

Drain Saddle Installation

Step 11

Step 12

Step 13

The drain saddle must be installed at least 1 ½” above the nut

of the P-Trap elbow or cross bar from the garbage disposal to

insure proper drainage. Using the 3/8” drill bit, drill into the drain

pipe at best available location as specified above, for drain saddle

installation. Take extreme caution to only drill through one side

of the drain pipe.

The small square black foam gasket with a circle cut out of the middle 

must be applied to the inside of the drain saddle. Remove sticky tape 

backing and stick to the drain saddle as shown.

1 Semicircle bracket with opening

2 Screws 

 

 

 

1 Foam gasket

2 Nuts for screws   

 

1 Semicircle bracket

Gather the pieces of the drain saddle:

Caution: Do not over tighten the screws.  It may crack the drain saddle.

If you have a garbage disposal, do not install the drain saddle near it.  
Installation of the drain saddle must be either above the garbage disposal, or 
if a second sink drain is available, install it above the cross bar on the second 
drain.  Installation of the drain saddle near a garbage disposal may cause 
the drain line to plug.  If no other installation of drain line is available, Premier 
offers drain line installation kit (part number 164020) that can be used with 
garbage disposals.

Caution:

The black 3/8” drain tube must be as SHORT and  STRAIGHT as possible to the drain 
saddle, making a downward slope from faucet to drain saddle to allow for proper 
drainage. This is a gravity fed line and if there is any  bend or dip in the tube, the rinse 

water  will not flow into the drain properly.  Water may back up and come out  the air 

gap hole in the back of the faucet.  

IMPORTANT:

Measure the 3/8” black tube from faucet to the drain saddle on the 

drain pipe and make a straight cut to the correct length.

Connect the black tube to the open quick connect fitting on the drain 

saddle by pushing the tube all the way to the tube stop.

Step 16

Step 15

Assemble the drain saddle around the drain pipe and align drain

saddle fitting opening with the hole drilled in the previous

step - you may use a small screwdriver to feed through the drain

saddle into the drain pipe to aid with the alignment. Using a Phillips

screw driver tighten the drain saddle bolts evenly and securely on
both sides.

Step 14

Содержание Premier WP4V-50

Страница 1: ...installation Your failure to follow any attached instructions or operating parameters may lead to the product s failure Watts Premier 8716 W Ludlow Drive Suite 1 Peoria AZ 85381 Phone 800 752 5582 www...

Страница 2: ...RO membrane This semi permeable membrane will take out TDS Sodium and a wide range of contaminants such as Chromium Arsenic Copper Lead as well as Cysts such as Giardia and Cryptosporidium and much m...

Страница 3: ...Installation 10 Drain Saddle Tube Connection 10 Reverse Osmosis Module Mounting 11 Green Tube Connection 11 Tank Elbow Installation 11 Connect Blue Tube from TANK Port on RO Module to the Tank 11 Con...

Страница 4: ...Operating Pressure Maximum 100 psi 7 0 kg cm2 Minimum 40 psi 2 80 kg cm2 pH Parameters Maximum 11 Minimum 2 Iron Maximum 0 2 ppm TDS Total Dissolved Solids 1800 ppm Turbidity 5 NTU Hardness Maximum 1...

Страница 5: ...1 104017 Sediment Filter 10 Inch 5M 4 ALT 1 560016 RO Membrane 35GPD 4 1 560018 RO Membrane 50GPD 5 3 113018 Filter Bowl 6 1 113035 Membrane Vessel 7 3 113041 O Ring Filter Bowl 8 1 113045 O Ring Mem...

Страница 6: ...hen drilling Watts accepts no responsibility for damage resulting from the installation of faucet Diamond tip bit recommended Marble Counter top We recommend contacting a qualified contractor for dril...

Страница 7: ...b and Install Spout Figure C This RO faucet is equipped with quick connect fittings for easy tube installation To connect tubes simply push them firmly into their corresponding fitting on the RO fauce...

Страница 8: ...ur faucet will have a good seal Disassembling your faucet is never recommended as this could void your warranty If it is necessary to remove the fitting at the end of the toggle bolt you must follow t...

Страница 9: ...Hot water will severely damage your system 3 8 Configuration With Brass Fittings Insert White Washer 1 2 Configuration Without Brass Fittings White Washer Hot Supply Cold Supply Hot Supply Cold Supply...

Страница 10: ...e second drain Installation of the drain saddle near a garbage disposal may cause the drain line to plug If no other installation of drain line is available Premier offers drain line installation kit...

Страница 11: ...quick connect fitting on the RO Manifold Make sure the tube is pushed in all the way to the tube stop See Picture Connect red faucet tube Green Tube Connection Step 14 Locate green tube attached to t...

Страница 12: ...aucet to flush the tank completely You will know that the tank is empty when the flow rate from the RO faucet is down to a trickle Repeat this step two more times The fourth tank can be used for drink...

Страница 13: ...pty to depressurize before attempting to remove filter housings Open the RO Faucet and allow water to drain from the tank until it is completely empty Insert the new Carbon Block filter White End Caps...

Страница 14: ...inutes then continue rinsing eye Call a poison control center or doctor for treatment advice Step 4 With the RO faucet in the closed position turn on the incoming water supply to the system by turning...

Страница 15: ...ntil it stops Follow the green tube away from the RO system to find the adapt a valve Step 2 Open the RO Faucet and allow water to drain from the tank until it is completely empty Step 3 Remove the ho...

Страница 16: ...uge is recommended Check Air Pressure in the Tank Important Step 3 Check air pressure only when tank is empty of water Step 1 Turn off the incoming water supply to the RO Open the RO Faucet and allow...

Страница 17: ...or drain Air gap faucet Inherent sound with air gap faucets Location of drain saddle See diagram for proper location of drain saddle Higher capacity membrane Normal with high capacity membrane High wa...

Страница 18: ...omplete list of VOC s Recovery 13 7 Daily Production Rate 9 86 GPD Efficiency 6 8 Depending on water chemistry water temperature and water pressure Premier s R O Systems production and performance wil...

Страница 19: ...ne where it does convert trivalent arsenic to pentavalent arsenic may not convert all the trivalent arsenic in to pentavalent arsenic If you get your water from a public water utility contact the util...

Страница 20: ...ONITRILE 98 0 024 0 0006 DICHLOROACETONITRILE 98 0 0096 0 0002 TRICHLOROACETONITRILE 98 0 015 0 0003 HALOKETONES HK 1 1 DICHLORO 2 PROPANONE 99 0 0072 0 0001 1 1 1 TRICHLORO 2 PROPANONE 96 0 0082 0 00...

Страница 21: ...urchase __________ Date of Install ___________ Installed by __________________ Serial No _____________________ Date 1st stage Sediment 6 months 2nd stage Carbon 6 months 4th stage VOC Block 1 year 3rd...

Страница 22: ...exceed 105 degrees F 40 degrees C 7 Incoming TDS Total Dissolved Solids not to exceed 1800 ppm 8 Do not use with water that is micro biologically unsafe or of unknown quality without 9 adequate disinf...

Отзывы: